8 Control panel settings IniControl 2
8.1
List of parameters
8.1.1
User menu
Fig.37
1
2
MW-2000435-1
3
2
1 Sub-menu available
2 Name of the PCB or circuit
3 Setting parameters
Tab.6
List of User sub-menus
Sub-menu
Description
Name of the PCB or cir
cuit
Main heating circuit
Additional heating circuit B
Additional heating circuit C
Domestic hot water circuit
Central unit PCB CU-OH01
Additional PCB for circuit B
Additional PCB for circuit C
Control panel HMI
Note
CP : Circuits Parameters = Heating circuit parameters
Tab.7
List of parameters in the
/
/
sub-menus of the User menu
Parameter
Description
Factory setting
Factory setting
Heating water flow temperature set point for the zone heated if no
outside temperature sensor has been connected.
For the
PCB: Can be set from 7 to 90°C
75°C
40°C
Post-operation time of the circuit pump
Can be set from 0 to 20 minutes
3 minutes
4 minutes
Room temperature set point in reduced mode
Can be set from 5 to 30°C
16°C
16°C
Room temperature set point in comfort mode
Can be set from 5 to 30°C
20°C
20°C
Do not modify this setting.
6°C
6°C
Do not modify this setting.
21°C
21°C
Do not modify this setting.
22°C
22°C
8 Control panel settings IniControl 2
7642056 - v05 - 30012017
EFU C