Nuvo-3000 Series User’s Manual
Copyright © 2013 Neousys Technology Inc. All Right Reserved.
Page 76 of
101
Mode 2 / Mode 3 / Mode 4 / Mode 5
Mode 2 ~ Mode 5 are ignition power control modes with various power-on delay and
power-off delay. Each mode supports a hard-off timeout of 10 minutes.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
2
10 seconds
10 seconds
10 minutes
3
30 seconds
1 minute
10 minutes
4
30 seconds
5 minutes
10 minutes
5
30 seconds
30 minutes
10 minutes
Mode 6 / Mode 7
Mode 6 and Mode 7 are ignition power control modes with very long power-off delay.
Both modes support the feature of “smart off-delay”, which automatically detect system
status during power-off delay duration and cut off system power if system is off in prior
to power-off delay expired.
Mode
Power-on Delay
Power-off Delay
Hard-off Timeout
6
30 seconds
2 hours
10 minutes
7
30 seconds
5 hours
10 minutes