4.2.4 Firmware update of the sensor

 

 

  Wait until the sensor is detected 

 

  To switch to the 

«Control» menu click the icon  

 .

 

  Click on 

«Firmware update»

 

  If the sensor firmware version is less than the version of the current firmware available on 

the update server, the message 

«Update available» will be displayed indicating the current 

version. 

  To start the update process, click 

«update». 

To check the relevance of the firmware version and download it from the update server, the 

application needs Internet access. At the same time, traffic may be consumed or a fee for 

communication services may be charged by your mobile network operator. The 

«ADM-BLE 

Configurator

»  application  does  not  support  a  permanent  connection  via  the  Internet. 

Synchronization  of  firmware  versions  is  performed  no  more  than  once  a  day.  The  sensor 

firmware has a size of not more than 100 kB. 

 

4.3 Using the sensor together with the trackers 

АDM007 and ADM333, that 

contains BLE interface

 

 

4.3.1 Method of sensors catching

 

 

The sensor is catched on the tracker side. By default, the sensor is configured to measure  

temperature, humidity and illumination.  

Sensor  integration  with  the  tracker  ADM007  or  ADM333,  that  contains  BLE  (hereinafter 

referred to as a tracker) is performed via sending commands via GPRS or SMS. It is also possible 

to configure the sensor in the graphical interface of the 

«ADM Configurator» application using the 

Bluetooth interface.  Up to 5  sensors of  ADM35(H)  can be connected to one tracker. One sensor 

can be connected to several trackers simultaneously 

Catching the sensor can be performed manually and automatically. 

 Manual  catching  requires  entering  addresses  of  each  sensor.  This  method  is  suitable  for 

the  situation  when  in  the  Bluetooth  coverage  range  of  the  tracker  there  are  activated  sensors, 

which should not be caught by the tracker. 

Automatic  catching  is  based  on  searching  for  the  sensors  and  automatic  record  of 

addresses  of  all  sensors  found.  This  method  is  suitable  for  the  situation  when  in  the  tracker 

coverage Bluetooth range there are only needed sensors.   

 

Содержание ADM35

Страница 1: ......

Страница 2: ...elated tracker from the devices manufactured by Neomatica LLC The Operation manual is designed for professionals who have familiarized themselves with the rules of repair and installation works execut...

Страница 3: ...10 4 2 3 Report generation in ADM BLE Configurator application 12 4 2 4 Firmware update of the sensor 13 4 3 Using the sensor together with the trackers DM007 and ADM333 that contains BLE interface 13...

Страница 4: ...cal features The ADM35 model figure 1 measures temperature more accurately its temperature measuring element has higher protection from moisture but the model does not contain a measuring element to m...

Страница 5: ...iver sensitivity 96 dBm Data exchange technology Bluetooth Low Energy BLE Bluetooth Low Energy Long Range BLE Long Range Coverage in the mode of BLE up to 100 m in line of sight Coverage in the mode o...

Страница 6: ...pe of Hall detector discrete omnipolar Frequency range of radio interface 2400 2483 5 Hz Transmitter power up to 8 dBm Receiver sensitivity 96 dBm Data exchange technology Bluetooth Low Energy BLE Blu...

Страница 7: ...correspond to the operating conditions of the sensor If you need to fasten more tightly the methods listed above can be combined The transparent lid of the sensor should be clean Impurities present o...

Страница 8: ...Range technology allows increasing the distance from the sensor to the receiving device and to increase the reliability The receiving device should support data receipt via such technology BLE techno...

Страница 9: ...s is due to Google requirements for applications that provide data exchange with BLE devices since BLE technology includes positioning by BLE beacons You also need permission for the access of photos...

Страница 10: ...ination Humidity only for ADM35H Hall element Battery voltage Firmware version RSSI level of received radio signal The time passed since the last data message was received LR data received by Bluetoot...

Страница 11: ...r To save battery power it is not recommended to activate this detector if it is not planned to be used Humidity sensor Enabling or disabling the humidity sensor Illumination sensor Enabling or disabl...

Страница 12: ...in ADM BLE Configurator application Wait until the sensor is detected and see the date and time of the last data synchronization Only the synchronized data will be recorded in the report Synchronize t...

Страница 13: ...he trackers DM007 and ADM333 that contains BLE interface 4 3 1 Method of sensors catching The sensor is catched on the tracker side By default the sensor is configured to measure temperature humidity...

Страница 14: ...in the end of the list BLESENSOR 0 clear the list BLESENSOR display the list of addresses added in the tracker Example of commands entering BLESENSOR 0 0C61CFEF5E31 add the address 0C 61 CF EF 5E 31 i...

Страница 15: ...without filters BLEAUTOCATCH automatic search of all supported BLE sensors without filters BLEAUTOCATCH 0 stop current search 4 3 5 Getting information from the sensors caught BLESENSORINFO command a...

Страница 16: ...40 and relative humidity at most 85 After transportation of the sensors in sub zero temperatures they should be stored at room temperature within 24 hours 6 Warranty The manufacturer guarantees the p...

Страница 17: ...d individual package is possible 8 Disposal Disposal of the sensor and discharged battery is performed according to national and local norms and requirements 9 Scope of supply Device name Quantity Com...

Страница 18: ...o avoid problems we recommend at first to update the tracker to the latest available firmware version Connect the Teltonika device to the Configurator by any convenient way In the left menu find the i...

Страница 19: ...7 2021 19 In the MAC field enter without entering a colon the MAC address of the ADM sensor from which the tracker will receive and process the data The table of data received from ADM sensor should b...

Страница 20: ...rver 2 calculation formulas are used for two ranges of incoming values For the range of values from 0 to 32767 use the formula X 0 01 For the range of values from 32768 to 65535 use the formula X 0 01...

Страница 21: ...ystem language 4 If connection failed try to connect again The connection will be set up as soon as the sensor sends the first Advertising message once per 15 seconds by default 5 After connection on...

Страница 22: ...If the command is read correctly the command name itself will be duplicated in TX Characteristic without a parameter sf x activation of additional sensor functions Only the Hall element To enable it s...

Отзывы: