Blade activation time setting test (18)
8.2.8
Press
key
9
until number
18
(even folding) appears on the display.
Press
key
7
to start the real test. The number of the parameter of the even folding
clutch will appear (parameter 13).
Keys
8a
and
8b
increase/decrease the activation time-parameter for the even
folding clutch.
Press
key
10
to enable/disable the test.
If the parameter is high the time needed for the activation of the
odd folding clutch is very high, the blade rests on the rollers for
too long and could therefore stop the motor. If the motor stops,
press key
10
to disable the motor, decrease the parameter and
try to start the motor again. We recommend to increase the
parameter no more than 5 steps at a time. The new parameter is
memorised each time key
10
is pressed.
Press
key
9
to stop the time setting test for the activation of the odd folding clutch.