7
4. Installation Instruction
4.1 Power Supply Connection
IN12 power connection is single phase 220V, please connect it against local users
actual situation. Connection as below picture: Open the cover on bottom right corner,
L stands for the live wire, N stands for the zero wire, and E stands for the ground wire,
connect to the 220V power supply. According to the wiring requirements, the L
should be connected to one live wire, and the N should be connected to one zero wire;
the E should be connected to one ground wire properly.
4.2 Installation Attentions
♦ Put down the bearing foot cup, level it and then connect it to the power supply,
voltage requirement 220V
;
♦ The electricity wire need no less than 2.5mm
2
, it’s better to directly use 4mm
2
(If
2.5mm
2
, then it can only connect with one set of IN12 Reflow oven, other equipment
Will not be allowed to connect together.
♦ The machine should be set in standard SMT workshop, stay away from flammable
and explosive if couldn’t meet previous requirements.
♦ Exposed wire harness should be well protected, prohibit to expose at the passage or
flue in case of causing any accident.
E N L
Air switch
RCD (Leakage
protector)
Wire
connection
Содержание IN12
Страница 6: ...5 3 Main Parts 3 1 Reflow Oven Main Body 3 2 Operating Panel...
Страница 7: ...6 3 3 Cover and Heating Zone 3 31 Heating Zone...
Страница 18: ...17 Figure 4 Set too high low temperature of active zone Figure 5 Soldering too much little...