CHAPTER 1. OMNI DRIVE MODULE
1.5. CONFIGURATION
In case you cannot connect to the amplifier, please check the following:
• Amplifier power: Is the amplifier connected to a sufficient power supply and is the power supply turned on?
In case the module is connected to a laboratory power supply: Is the current limit high enough to provide the
inrush current and a sufficiently fast rise of the logic supply voltage?
• Cable: Is the computer actually connected to the correct amplifier? When handling several drives in a row it
sometimes happens that only the power supply is connected to the next module while the configuration cable is
still plugged to the previous module.
• Baud rate: The baud rate of the serial connections has been changed to 57.6 kBaud to make working with the
modules more convenient. The default baud rate of the
Composer
is only 19.2 kBaud.
• COM port: Try other COM port numbers. If a USB-to-serial converter or a similar device is used, please check
which number has currently been assigned to the interface. Close the
Composer
, re-connect the converter and
restart the
Composer
.
Use the button
Disconnect
on the right end of the main toolbar to close the connection to the amplifier. Disconnect
button is shown below:
16
Содержание Omni Drive Module
Страница 1: ...Omni Drive Module Neobotix GmbH Apr 14 2022 ...
Страница 10: ...CHAPTER 1 OMNI DRIVE MODULE 1 4 ELECTRICAL INSTALLATION Fig 1 Dimensions of the Omni Drive Module 7 ...
Страница 11: ...CHAPTER 1 OMNI DRIVE MODULE 1 4 ELECTRICAL INSTALLATION Fig 2 Bottom view of the Omni Drive Module 8 ...
Страница 12: ...CHAPTER 1 OMNI DRIVE MODULE 1 4 ELECTRICAL INSTALLATION Fig 3 Top view of the Omni Drive Module 9 ...