19
www.neo-tools.com
„
9.
”
Button
To turn on or off the backlight, press and hold this button for about 2 seconds.
The backlight will turns off automatically about 15 seconds later
after you turn on it.
10.
Button
After pressing the button, the present reading is held on the display, meanwhile
is displayed
on the LCD as an indicator. To exit the Hold Mode, press the button again and the indicator
will
disappear.
11.
Button
To hold the maximum value, press this button, and
will appear as an indicator, the meter will hold
the maximum value of all readings taken since the button was pressed. To exit the maximum value hold
mode, just press this button gain, and
will disappear.
In some ranges, the maximum value hold mode is not available.
GENGRAL SPECIFICATION
Display
: LCD, 1999 counts, updates 2-3 times/sec
Overrange Indication
: „OL” shown on the display
Battery
: 1.5V X 3, AAA
Polarity Indication
: „-” displayed automatically
Low Battery Indication
:
shown on the display
Operating Temperature
: 0°C to 40°C, <75%RH
Storage Temperature
: -10°C to 50°C, <85%RH
Dimensions
: 158 X 75 X 35 mm
Weight
: about 200g (including battery)
SPECIFICATIONS
Accuracy is specified for a period of one year after calibration and at 18°C to 28°C, with relative humidity <
75%.
DC Voltage
Range
Resolution
Accuracy
200mV
0.1mV
± (0.8%+5)
2V
0.001V
20V
0.01V
200V
0.1V
600V
1V
± (1%+5)
Input Impedance: 10M
Overload Protection: 600V DC/AC rms
( 200mV range : 250V DC/AC rms )
Max. Input Voltage: 600V DC