WIZORD 4
Standard Operating Procedure
S T A N D A R D O P E R A T I O N
TURNING YOUR UNIT ON / OFF:
In the default state, the energizer can be turned on or off by holding the
plastic tab over the corresponding logo on the fascia of the unit. The unit will
beep once when turned on and twice when turned off.
FENCE STATUS INDICATION:
The unit will indicate that a condition is currently active (fence fault, gate
open, or service condition) if the corresponding LED is flashing; eg. if the
fence LED is flashing, the fence voltage is currently not satisfactory. If the
fence alarm indication LED is lit continuously, there was a fence alarm
condition previously but the fence voltage is now satisfactory. Similarly, if the
gate alarm indication LED is lit permanently, the gate opening time exceeded
the entry delay period but is now closed. If the gate indication LED is
flashing, the gate is still open.
ALARM INDICATION:
The fence and gate inputs are configured to trigger external alarms and the
internal buzzer. The service condition will activate the buzzer only. Be aware
that, should there be a prolonged power failure, the battery may run low and
cause the service light to flash. If the mains interruption is sufficiently long,
the unit will shut down and there will be no indication of mains failure.
TOGGLE FUNCTION:
In the event of the unit being switched off by the plastic tab while a fault is
active, the unit will silence all alarms. On turning the unit on again the
corresponding LED’s will indicate the fault, but no alarm outputs will be
triggered. This provides the user with the facility to leave the unit on if no
service personnel are available. Should the unit be turned off and on again,
the alarm outputs will activate after the default periods. On turning the unit
off again, the outputs will again be disabled. Users must be wary of this
toggle function. The user does not need to concern them self with the toggle
function if the unit is switched off and on again under normal conditions, as
per table 1 (i.e. No alarm condition active).
BUZZER:
The buzzer has a different cadence for the fence alarm and gate alarm.
SERVICE INDICATION:
The service indicator should remain off during normal operation. If it is lit
due to an obvious condition, such as prolonged mains failure, simply turn the
unit off and on again. Should the condition persist, refer to your installer.
The unit has built-in diagnostics to assist the installer.