![Nemtek MERLIN STEALTH M113S Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/nemtek/merlin-stealth-m113s/merlin-stealth-m113s_user-manual_718604007.webp)
7
indicator notifies the user that the fault no longer exists. In the latter case simply turning the
energizer on again will clear the memory condition. If the flashing alarm condition cannot be
resolved, the alarm will be activated irrespective of the number of times the unit is turned On
or Off. The Master user can bypass alarm conditions. A reset user will only reset the alarm
outputs and not change the On/Off state of the energizer.
CHANGE THE VOLTAGE ON THE FENCE
Enter your PIN (master only) and press the
*
key, enter the digit
3
, then press the
#
key.
When the fence is on and in low voltage mode, the red
ON
light will flash. The red
ON
light
will stay permanently lit if the fence is in high voltage mode. Use the low voltage mode when
children are in the fence vicinity.
BYPASS THE FENCE ALARM
Enter your PIN (master only) and press the
*
key, enter the digit
1
, then press the
#
key.
The
FENCE ALARM
light will start flashing slowly to confirm the fence alarm is bypassed.
To cancel the bypass, repeat the same sequence of keys.
BYPASS THE SIREN AND STROBE LIGHT (SILENT ALARM)
Enter your PIN (master only) and press the
*
key, enter the digit
4
, then press the
#
key.
The beeper in the control panel will still be active.
UN-BYPASS THE SIREN AND STROBE LIGHT
Enter your PIN (master only) and press the
*
key, enter the digit
7
, then press the
#
key.
MAKE THE GATE ALARM IMMEDIATE(Both Gates)
Enter your PIN (master only) and press the
*
key, enter the digit
2
, followed by the digit
7
,
then press the
#
key. The
GATE ALARM
light will start flashing, with a cadence of one flash
every 5 seconds, to confirm the gate alarm is immediate.
MERLIN STEALTH
M113S
Using your KEYPAD
PDF created with pdfFactory trial version
www.pdffactory.com