background image

 

 
 
 

 
 
 

 
 

 
 
 

 

 

 

 
 

 

 
 

M113S 

Users Manual 

 
 

 
 

 

 
 

 
 
 

 
 
 

 
 
 
 
 

 
 
 

 
Revision 1.0 
Date: 29 January 2007 

GROUP OF COMPANIES

 

MERLIN  STEALTH M113S

 – 

Electric Fence

 

Energizer 

PDF created with pdfFactory trial version 

www.pdffactory.com

Содержание MERLIN STEALTH M113S

Страница 1: ...M113S Users Manual Revision 1 0 Date 29 January 2007 GROUP OF COMPANIES MERLIN STEALTH M113S Electric Fence Energizer PDF created with pdfFactory trial version www pdffactory com ...

Страница 2: ...KEYPAD 5 OPERATION WITH A KEYPAD 5 USING YOUR KEYPAD KEYPAD 6 10 FENCE INDICATOR LIGHTS 11 WHAT THE ENERGIZER LIGHTS INDICATE 12 WHAT THE KEYPAD LIGHTS INDICATE 13 DOCUMENT REVISION HISTORY 14 No user serviceable parts inside the energizer PDF created with pdfFactory trial version www pdffactory com ...

Страница 3: ...documentation and energizer features can be viewed on our website at www nemtek com The M113S Energizer has patented energy control and safety features Refer any questions and special requirements to suitably trained installers Electric fencing can be lethal Avoid head contact with the fence Get the installer to explain the options of current limiting resistors the enhanced safety features of the ...

Страница 4: ...Warehouse Unit 4 Meadowdale Park Cnr Herman Dick Kemp Roads Meadowdale Edenvale Gauteng South Africa The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse L I M I T A T I O N O F G U A R A N T E E The guarantee does NOT apply to defects resulting from acts of GOD modifications made by the buyer or any third party misuse neglect abus...

Страница 5: ...ly turning the energizer On again will clear the memory condition A flashing alarm light illustrates that the fault condition persist In this case rectify the condition which caused the alarm To reset and clear the memory condition turn the energizer On and Off and On again Only if the alarm condition is resolved will the energizer operate without alarm activation OPERATION WITH A KEYPAD The energ...

Страница 6: ...hed off Use the Gate Bypass function if these inputs are to be ignored USING YOUR KEYPAD SWITCH THE FENCE ON OFF Master Normal User To switch the fence On or Off enter your four digit PIN followed by the key If the red ON light is lit or flashing the fence is energized Don t pause for more than 5 seconds while entering the digits or the control panel will reject your PIN number If you make a mista...

Страница 7: ...re in the fence vicinity BYPASS THE FENCE ALARM Enter your PIN master only and press the key enter the digit 1 then press the key The FENCE ALARM light will start flashing slowly to confirm the fence alarm is bypassed To cancel the bypass repeat the same sequence of keys BYPASS THE SIREN AND STROBE LIGHT SILENT ALARM Enter your PIN master only and press the key enter the digit 4 then press the key...

Страница 8: ...tes MAKE THE GATE ALARM DELAYED Gate 1 Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 1 then press the key The default gate delay is 30 seconds MAKE THE GATE ALARM DELAYED Gate 2 Enter your PIN master only and press the key enter the digit 2 followed by the digit 4 followed by the digit 2 then press the key The default gate delay is 30 ...

Страница 9: ... ON Gate2 Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 3 then press the key If the chime is on the keypad will beep three times if the gate opens and twice if it closes TURN THE GATE CHIME OFF Gate2 Enter your PIN master only and the key enter the digit 2 enter the digit 8 enter the digit 4 then press the key No audible indication of gate opening or cl...

Страница 10: ...NGING A USER PIN Enter your master PIN press the key enter the digit 0 then press the key Enter the user number 0 6 and push the key User number 0 is the master PIN that has system configuration rights i e bypass of alarm conditions etc Enter that user s new PIN and press the key Enter the new PIN again and press the key If the new PIN is accepted the control panel will beep four times If you make...

Страница 11: ...OD as the effectiveness of the fence is maintained Should the fence loading be such that the fence voltage is insufficient to be a deterrent then the ALARM indicator will remain lit or have a fast flash and the alarm outputs if enabled will activate FENCE1 Fence voltage acceptable Fence voltage questionable Inspect fence and do maintenance If lit permanently the fence dropped below acceptable volt...

Страница 12: ...roblem on fence FENCE BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm switched off GATE IMMEDIATE 1 FLASH EVERY 5 SECONDS Appropriate gate input is in immediate mode SILENT ALARM 1 SHORT FLASH EVERY 5 SECONDS Siren or strobe light not activated by alarm GATE2 CONTROLS FENCE VOLTAGE Gate2 LONG FLASH EVERY 5 SECONDS Gate 2 closed fence i...

Страница 13: ...BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm switched off GATE IMMEDIATE 1 FLASH EVERY 5 SECONDS Appropriate gate input is in immediate mode SILENT ALARM 1 SHORT FLASH EVERY 5 SECONDS Siren or strobe light not activated by alarm GATE2 CONTROLS FENCE VOLTAGE Gate2 LONG FLASH EVERY 5 SECONDS Gate 2 closed fence in low voltage mode Gat...

Страница 14: ...14 MERLIN STEALTH M113S Document Revision History DOCUMENT REVISION HISTORY Revision 1 0 29 January 2007 End of document PDF created with pdfFactory trial version www pdffactory com ...

Отзывы: