22
FG7C CONTROLLER FG7 WEB INTERFACE
You can only load guf5e files for firmware updates, image13r370.png files for site images
and the mapping files itoemap.txt or etoimapplus.txt
3)
Once the file is selected you have two options:
Press “Get File” and re-enter the installer password and the selected file will be down
loaded into the FG7 or
Click on “View File Only” and press “Get File”. In this case the file chosen will be
displayed on the computer screen but not downloaded to the FG7. If you are satisfied
with the file, press the back button on your browser un-tick the “View File Only” and
press the “Get File”. Enter the installer password and the file will be uploaded to the FG7.
4)
After the file is loaded one has to reset the FG7 and this can be accomplished by
pressing “Reset FG7 and Use Files”. The FG7 will reset and after restarting ready for use.
LCD touchscreen or HDMI
Through the web interface one can change the LCD touchscreen display to an HDMI display or
vice versa.
1)
Enter on the address bar of the browser after the IP address /nemupload.cgi.
As an example with the IP address of the control unit being 10.0.0.20 one would enter in
the browser 10.0.0.20/nemupload.cgi
2)
Enter the installer password
The installer configuration screen will appear.
3)
Click on HDMI or LCD screen as required. The display will change to HDMI or LCD
touchscreen.
ENERG APP / TW APP / TWNODE APP
It is possible to toggle through the web interface the application in the FG7. The FG7
should have been set for the use with energizers (ENERG APP) but by clicking on TW
APP or TWNODE APP it can be set for use with Taut-wire sensors instead of energizers.
THIRD PARTY INTEGRATION
The FG7 can communicate with third party software such as Nemtek Druid FenceProbe. The
communication is done through the Ethernet port on the blue control board of the FG7.
The IP of the computer running the software should be in the same range as the IP of the FG7
(the IP of the FG7 can be changed under the Net tab).
Once connected the third party software will take control of the system, however the FG7 can
still issue commands and the third party will see the change in the system and can accept it or
override it by reversing the command of the FG7.
If there are IO cards in the system then the mapping of the third party software is followed. It is
however advisable to load the identical mapping into the FG7 so that if the communication to the
software is lost the commands from inputs and the relay outputs on the IO card(s) will remain