14
FG7C CONTROLLER: Programming the FG7C
USER TAB SETTINGS
Under the user tab are several buttons for setting:
Installer and User PIN numbers (see user manual)
Time (see user manual)
Saving the Log (see user manual)
Defaulting to factory settings
FACTORY DEFAULT
Under the USER Tab you can reset the FG7 to Factory default settings by pressing the default
button the IP address will be reset to 10.0.0.20 and all pin settings will default back to the
numbers as stated in the user manual.
SYSTEM TAB SETTINGS
Under the system tab there are a number of settings which can be selected by clicking on the
setting required and the tick box next to the setting will then show a tick indicating that the
setting is selected. The following settings can be selected:
Audible alarm
Alarm Sensor mode
Show sync loss
Nemlink
Proxy
AbsoluteIO
Failsafe Off LV
AUDIBLE ALARM
The buzzer inside the FG7 is enabled when the Audible Alarm tick box is ticked. The buzzer will
sound when there is an alarm or service condition. If unticked the buzzer is disabled.
ALARM SENSOR MODE
If the alarm sensor mode is ticked then alarm and service conditions will only show as long as
the alarm or service condition is present. When the error clears the screen will show a good
condition again. If Audible alarm is ticked the buzzer will sound but will require a manual
energizer reset from the global screen.
SHOW SYNC LOSS
When ticked the FG7 will alarm, log and show under service that synchronization between
energizers in the system has been lost.