FG7C CONTROLLER: Programming the FG7C
J3 Four way connector for TTL connection
J4 Three way connector for RS 485 (out)
J5 Three way connector for RS 485 (in)
J6 Three way connector for connection to the taut wire system
The connectors on the communication board are self-explanatory. However, if communication will
be made through a separate NemLink card, then the connector J2 should be used (jumper
selection TTL Serial). Also note that the FG7-Druid does not support RS485 multidrop, only daisy
chain, so there are RS485 OUT and RS485 IN terminals. The TAUT Wire terminal is not used in
the FG7 Druid controller.
PROGRAMMING THE FG7C-DRUID
The FG7C-Druid should be programmed with the number of energizers as well as the IO cards in
the system.
If required a graphic site image can be loaded on the FG7C-Druid and zones (sectors) as well as
Gate lines can be drawn on the image.
CONFIGURE THE NUMBER OF ENERGIZERS ON THE
NETWORK
1)
On the FG7, press the PIN tab on the top screen and select
▼
Installer, enter the
appropriate PIN number and press Enter. Check that Installer stays on the screen and
has not revert back to select.
2)
Press the System tab on the top of the screen and use the
▼
and
▲
markers next to the
number of energizers to select the correct number of energizers in the network.
Press Save No of Energizers.
3)
If jumper JP1 and JP3 on the display board are set to auto reset (normal operation), then
after about two minutes the application will restart. Otherwise one can push the B3-PWR
button and this will close the application and after the Nemtek logo has disappeared from
the screen you press the B3-PWR button again to restart the unit.
4)
Check under the system tab that the number of energizers is now correct.
CONFIGURE THE NUMBER OF IO CARDS ON THE NETWORK
1)
On the FG7, press the PIN tab on the top screen and select
▼
Installer, enter the
appropriate PIN number and press enter. Check that Installer stays on the screen and
has not revert back to select.
2)
Press the System tab on the top of the screen and use the
▼
and
▲
markers next to the
number of IO cards to select the correct number of IO cards in the network.
Press Save No of IO cards.