If the energizer has a negative voltage output or in some instances,
where the ground fence wire is measured, the negative voltage
indicator will be displayed.
•
If the current in the fence wire is less than 2A, no fault direction arrows
will be shown.
•
If the Fence Meter does not detect an energizer pulse for 10 seconds,
the meter will automatically switch off.
•
Measurements taken in close proximity (less than 1m) to the energizer
might not be accurate.
•
If only a voltage measurement is desired, it is not necessary to place
the wire in the measuring pin slot, any contact to the metal strip will be
sufficient.