6.2
Short-circuit Fault
•
Start as close as possible to where the high voltage (HV) leads from the
energizer connects to the electric fence and take a measurement on the
live wire.
•
The fence current will be significantly higher compared to a healthy
fence.
•
Take a measurement at regular intervals along the fence, while moving
away from the energizer.
•
When the measurement shows a significant drop in current, the fault
should be between the current and the previous measurement points.