V
A
W
-
-
mV
mV
mS
-
-
mS
mS
mS
-
-
mA
-
-
-
-
-
-
V
-
-
-
-
-
-
A
-
-
%
A
MODEL
OUTPUT VOLTAGE (*1)
OUTPUT CURRENT (*2)
RATED OUTPUT POWER
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
RIPPLE
RECOVERY TIME (*4)
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwidth)
(pk to pk 20MHz Bandwidth)
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwidth)
INPUT VOLTAGE (*8)
INPUT CURRENT (*6)
INPUT CURRENT HARMONICS
POWER FACTOR (TYP)
EFFICIENCY (*6)
INRUSH CURRENT (*7)
100/200V
VOLTAGE
CURRENT
STATUS
UP PROGRAMMING RESPONSE TIME
FULL LOAD
NO LOAD
RESOLUTION
ACCURACY
RESOLUTION
ACCURACY
VOLTAGE
CURRENT
CONSTANT
VOLTAGE
CONSTANT
CURRENT
DOWN
PROGRAMMING
RESPONSE TIME
PROGRAM-
MING
(*3)
DISPLAY
OVERVOLTAGE PROTECTION (*5)
HOLD UP TIME
OUTPUT PROTECTIONS
INPUT
ZUP60-
7
0 ~ 7
10
5.6 / 2.7
80 / 84
0 ~ 12
15
5.6 / 2.7
80 / 84
0 ~ 20
30
5.6 / 2.7
79 / 83
0 ~ 40
50
5.6 / 2.7
79 / 82
0 ~ 66
0.005% +2mV from no load to full load, constant input voltage
0.005% +1mV from 85-132VAC or 170-265VAC, constant load
5
50
30ppm/
C from rated voltage following 30-minute warm-up
0.01% +2mV change in output over 8-hour interval under constant line, load and ambient
temperature following 30-minute warm-up
50mS (From zero volts to full scale, resistive load, current setting at max.)
50
100
5.6 / 2.7
74 / 77
15
15
15
15
15
ZUP60-
3.5
0 ~ 3.5
5
2.9 / 1.4
75 / 79
0 ~ 6
7.5
2.9 / 1.4
76 / 80
0 ~ 10
15
2.9 / 1.4
74 / 78
0 ~ 20
25
2.9 / 1.4
73 / 77
0 ~ 33
198
396
200
400
200
400
216
432
210
420
50
3.0 / 1.5
69 / 72
15 / 30
15 / 30
15 / 30
15 / 30
15 / 30
ZUP36-
12
ZUP36-
6
ZUP20-
20
ZUP20-
10
ZUP10-
40
ZUP10-
20
ZUP6-
66
250
0 - 7.5
1
350
0 -13
0.5
400
0 - 24
0.2
0.01% + 5mA for load voltage change equal to unit voltage rating , constant input voltage.
0.01% +2mA from 85-132VAC or 170-265VAC, constant load
20mS at 100V/200VAC, rated output voltage and output current
100ppm/
C from rated current following 30 minute warm-up
O
Better than 0.028% of rated output voltage
0.02% + 5mV
0.02% + 8mV
0.02% + 12mV
0.02% + 26mV
0.02% + 35mV
0.4% + 40mA
Better than 0.03% of rated output current
0.02% +5mA change in output over 8-hour interval under constant line, load and ambient
temperature following 30 minute warm-up
3 digits (6V, 20V, 36V, 60V) 3.5 digits (10V) accuracy: 0.2% +/- 2 digits
3 digits accuracy: 0.5% +/- 3 digits
CV/CC, Alarm, Fold, Local/Remote, ON/OFF
Over Voltage, Over Temperature, Foldback
85 ~ 265VAC Continuous, 47 ~ 63Hz
Complies with EN61000-3-2, Class A
0.99 at 100/200VAC, 100% Load
500
0 - 40
0.2
750
0 - 66
0.2
0 ~ 6
0 ~ 10
0 ~ 20
0 ~ 36
0 ~ 60
ZUP6-
33
CHAPTER 2 SPECIFICATIONS
2.1 SPECIFICATIONS: 200W/400W Series
7
O