3.8.2 Pin Description
3.8.3 External Control Connector - Technical description
1. Connector type : AMP, Part No: 102617-5 14 contacts, double row.
2. Receptacle : AMP, Part No: 87631-9, Polarized, 14 contacts, double row.
3. Receptacle contacts : AMP, Part No: 87523-5 (strip form) or 87523-6 (loose piece).
4. Wires : AWG: 24 to 20.
5. Hand tool for wire connection : AMP, Part No: 90202-2.
6. Applicator for stripper/crimper machine : AMP, Part No: 466905-1
#
Name
1 RCVP
2 RCCP
3 VRFI
4 VCCP
5 VRFV
6 VCVP
7 OUTPUT
GOOD
8 P
9 ON/OFF
10 COM
11 + LS
12 + S
13 - LS
14 - S
Description
Resistive Constant Voltage programming
Resistive Constant Current programming
Reference voltage for Constant Current control. (connected to
VCCP pin except external voltage or resistive programming).
Input of the Constant Current control circuit.
Reference voltage for Constant Voltage control. (connected to
VCVP pin except external voltage or resistive programming).
Input of the Constant Voltage control circuit.
Open collector output. 0~0.8V during normal operation, open at
fault condition (OVP, FOLD and Over-Temp.).
Parallel connection pin.
On/Off control pin.
Common pin for programming, On/off control and Output Good
signal. Internally connected to - Sense.
Positive Local sensing pin.
Positive Sensing pin for remote sense operation.
Negative Local sensing pin.
Negative Sensing pin for remote sense operation.
4.4.10
4.4.10
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.10, 11, 12
4.4.15
4.4.13
4.4.8
4.4.10, 11, 12
4.4.8
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
3.7.3, 4, 5, 6
Par.
Table3-3: External Control connector pin description
CAUTION
COM pin (10) is connected internally to the - Sense potential. Connection of the COM to another
potential or other than shown in this manual may cause damage to the power supply.
17