4
PERFORMANCE INSURANCE
PRODUCTION TOOLS
•
SHOW CONTROL
•
BACKUP SOLUTIONS
www.nemesis-research.com
CSC Preset
Button
Function
Message (Command)
1
Go
/cuelist/go
2
Stop
/cuelist/stop
3
Previous
/cuelist/prev
4
Next
/cuelist/next
5
Not used
OSCA-O4 Preset
Button
Function
Address
Integer Argument
1
Relay 1 ON
/relay/1
1
2
Relay 2 ON
/relay/2
1
3
Relay 3 ON
/relay/3
1
4
Relay 4 ON
/relay/4
1
5
All relays OFF
/relay/?
0
Advanced Mode – Inputs
By putting the device into advanced mode and navigating to the buttons menu the user can
specify custom messages (Commands) for each of your buttons. The OSCA can send up to two
arguments with each command. OSCA will automatically determine the format of the argument
based on the value. For example, 1 will be sent as an integer, 1.00 as a float and one as a string.
OSCA will also automatically read the entered OSC command (String) and determine what is the
address and argument(s). For further information please see
http://www.nemesis-
research.com/opensoundcontrol
A debounce time can be set per input in milliseconds. This is the time after the button is released
before it can be pressed again (the default is set to 250ms).
OSCA has a maximum length for the command which is 192 characters.
You can then select which destination you would like this command to be sent to. Each input can
send up to two commands, with each command being sent to one destination (To send the same
Command to 2 destinations send identical commands to each receiving device).
Output Settings
You can manually toggle the 16 outputs using the toggle switches on the outputs setting page.
This will also update if the output state is changed via OSC.
To turn outputs on and off send the following messages to the device via OSC (make sure the
transmitting device’s send port matches the device's listen port and is sending to the correct IP
address).