CSC Preset 

Button 

Function 

Message (Command) 

Go 

/cuelist/go 

Stop 

/cuelist/stop 

Previous 

/cuelist/prev 

Next 

/cuelist/next 

Not used 

 

 

OSCA-O4 Preset 

Button 

Function 

Address 

Integer Argument  

Relay 1 ON 

/relay/1  

Relay 2 ON 

/relay/2 

Relay 3 ON 

/relay/3 

Relay 4 ON 

/relay/4 

All relays OFF 

/relay/? 

 

Advanced Mode – Inputs 

By putting the device into advanced mode and navigating to the buttons menu the user can 

specify custom messages (Commands) for each of your buttons. The OSCA can send up to two 

arguments with each command.  OSCA will automatically determine the format of the argument 

based on the value. For example, 1 will be sent as an integer, 1.00 as a float and one as a string. 

OSCA will also automatically read the entered OSC command (String) and determine what is the 

address and argument(s). For further information please see 

http://www.nemesis-

research.com/opensoundcontrol 

 

 

A debounce time can be set per input in milliseconds. This is the time after the button is released 

before it can be pressed again (the default is set to 250ms). 

 

OSCA has a maximum length for the command which is 192 characters. 

You can then select which destination you would like this command to be sent to. Each input can 

send up to two commands, with each command being sent to one destination (To send the same 

Command to 2 destinations send identical commands to each receiving device). 

Output Settings 

You can manually toggle the 16 outputs using the toggle switches on the outputs setting page. 

This will also update if the output state is changed via OSC. 

 

To turn outputs on and off send the following messages to the device via OSC (make sure the 

transmitting device’s send port matches the device's listen port and is sending to the correct IP 

address). 

 

 

 

 

 

Содержание OSCA-IO16

Страница 1: ...1 PERFORMANCE INSURANCE PRODUCTION TOOLS SHOW CONTROL BACKUP SOLUTIONS www nemesis research com OSCA IO16 16 Way OSC General Purpose Input Output Interface USER GUIDE...

Страница 2: ...O 1 16 Indicate the current status of each general purpose output PSU 1 2 Indicate the current status of each dual redundant PSU NET Indicate the current status of the network connection ERR Indicate...

Страница 3: ...er settings Destination Settings On the Destinations page you can specify and name destinations a maximum of 5 when in advanced mode and 2 when in a preset which will be stored in the device s memory...

Страница 4: ...ad the entered OSC command String and determine what is the address and argument s For further information please see http www nemesis research com opensoundcontrol A debounce time can be set per inpu...

Страница 5: ...On for 500ms Firmware Update If connected to the internet you can use the Firmware update page to install the latest firmware from the Nemesis server Additional Information Incoming OSC OSCA will reac...

Страница 6: ...w nemesis research com 10 RLY3 COM 11 RLY3 NO 12 RLY4 NC 13 RLY4 COM 14 RLY4 NO 15 GND GPI 9 Pin Female D Sub Inputs 1 8 and 9 16 Closed contact to GND opto isolated input Option Function 1 Input 1 2...

Страница 7: ...ty with the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from Nemesis Audio WEEE Declaration Disposa...

Отзывы: