Network Settings 
 

Default IP settings 

IP Address 

192.168.1.253 

Subnet Mask  

255.255.255.0 

Gateway 

192.168.1.1 

DNS Main 

192.168.1.1 

DNS Backup 

192.168.1.1 

Network Device Name 

OSCA-IO16 

OSC Listen Port 

53500 

 

In order to change settings navigate to the device's IP address (default: 192.168.1.253) on the 

network using a web browser or use its network name (default: OSCA-IO16) and navigate to the 

“Network page”  

In order for changes to take effect press save and then restart (Please note if you have changed 

IP address or device name the page may not refresh, and you will need to open a new tab in your 

browser with the new user settings).  

Destination Settings 

On the Destinations page, you can specify and name destinations (a maximum of 5 when in 

advanced mode and 2 when in a preset) which will be stored in the device's memory. Please 

specify the IP address and OSC listen to port of the receiving device(s). 

Input Settings 

 

Each input can send up to four messages (Command), with each one sent to one of five 

destinations. (to send the same command to both destinations send identical command to each 

location) 

The device comes with three pre-sets built-in with predefined commands for CSC and Qlab and 

OSCA-O4. 

 

All commands in these pre-sets will be sent to Destination 1 and 2 (if specified on the 

destinations page) 

Qlab Preset 

Button 

Function 

Command 

Go 

/go 

Stop 

/panic 

Previous 

/playhead/previous 

Next 

/playhead/next 

Not used 

 

 

When using this pre-set it may be necessary to configure QLab to allow OSC connection access 

without a passcode. 

Содержание OSCA-IO16

Страница 1: ...1 PERFORMANCE INSURANCE PRODUCTION TOOLS SHOW CONTROL BACKUP SOLUTIONS www nemesis research com OSCA IO16 16 Way OSC General Purpose Input Output Interface USER GUIDE...

Страница 2: ...O 1 16 Indicate the current status of each general purpose output PSU 1 2 Indicate the current status of each dual redundant PSU NET Indicate the current status of the network connection ERR Indicate...

Страница 3: ...er settings Destination Settings On the Destinations page you can specify and name destinations a maximum of 5 when in advanced mode and 2 when in a preset which will be stored in the device s memory...

Страница 4: ...ad the entered OSC command String and determine what is the address and argument s For further information please see http www nemesis research com opensoundcontrol A debounce time can be set per inpu...

Страница 5: ...On for 500ms Firmware Update If connected to the internet you can use the Firmware update page to install the latest firmware from the Nemesis server Additional Information Incoming OSC OSCA will reac...

Страница 6: ...w nemesis research com 10 RLY3 COM 11 RLY3 NO 12 RLY4 NC 13 RLY4 COM 14 RLY4 NO 15 GND GPI 9 Pin Female D Sub Inputs 1 8 and 9 16 Closed contact to GND opto isolated input Option Function 1 Input 1 2...

Страница 7: ...ty with the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from Nemesis Audio WEEE Declaration Disposa...

Отзывы: