Nemesis OSCA-IO16 Скачать руководство пользователя страница 2

 

 

 

PERFORMANCE INSURANCE

 

PRODUCTION TOOLS    

    SHOW CONTROL    

    BACKUP SOLUTIONS

 

www.nemesis-research.com

 

Overview 

 

The OSCA-IO16 is a next generation multiple command destination show control solution 

featuring OSC Network input, with 16 isolated inputs and 16 relay outputs.

 

Front Panel 

 

GPI 1 -16

 – Indicate the current status of each general-purpose input. 

GPO 1 -16

 – Indicate the current status of each general-purpose output. 

PSU 1-2

 – Indicate the current status of each dual redundant PSU. 

NET 

– Indicate the current status of the network connection. 

ERR

 – Indicate an error status due to PSU failure or network not connected. 

Rear Panel Connections 

 

 

 
GPI 1 -8,  9-16

 – 9 Pin Female D-Sub for input connections. See Pin Outs section for details. 

GPIO1 -4, 5-8, 9-12, 13-16

 – 15 Pin Female D-Sub for output connections. See Pin Outs section 

for details. 

PSU 

 – 110-230V AC powerCON input 

NETWORK 

– etherCON RJ45 for network connection 

 

 

 

 

 

 

 

Содержание OSCA-IO16

Страница 1: ...1 PERFORMANCE INSURANCE PRODUCTION TOOLS SHOW CONTROL BACKUP SOLUTIONS www nemesis research com OSCA IO16 16 Way OSC General Purpose Input Output Interface USER GUIDE...

Страница 2: ...O 1 16 Indicate the current status of each general purpose output PSU 1 2 Indicate the current status of each dual redundant PSU NET Indicate the current status of the network connection ERR Indicate...

Страница 3: ...er settings Destination Settings On the Destinations page you can specify and name destinations a maximum of 5 when in advanced mode and 2 when in a preset which will be stored in the device s memory...

Страница 4: ...ad the entered OSC command String and determine what is the address and argument s For further information please see http www nemesis research com opensoundcontrol A debounce time can be set per inpu...

Страница 5: ...On for 500ms Firmware Update If connected to the internet you can use the Firmware update page to install the latest firmware from the Nemesis server Additional Information Incoming OSC OSCA will reac...

Страница 6: ...w nemesis research com 10 RLY3 COM 11 RLY3 NO 12 RLY4 NC 13 RLY4 COM 14 RLY4 NO 15 GND GPI 9 Pin Female D Sub Inputs 1 8 and 9 16 Closed contact to GND opto isolated input Option Function 1 Input 1 2...

Страница 7: ...ty with the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from Nemesis Audio WEEE Declaration Disposa...

Отзывы: