background image

 

Nemesis Orochi™ V1 
 

 

 

        

 

10 

 

Limited Warranty 

Terms and Conditions: This limited warranty is subject to the terms listed below.  

 

For warranty service - Call: (469) 466-2UVC, M-F, 8am-5pm CST 

 

1.

 

This warranty is void if:  

a.

 

The product serial number and/or labels are altered or removed 

b.

 

The product is modified in any manner that affects the reliability of the product 

c.

 

The product has been repaired or serviced by anyone other than a trained 

Nemesis technician  

d.

 

The product is damaged because it is not properly maintained as set forth in the 

product instructions, guidelines and/or user manual. 

 

2.

 

This is not a service contract, and this warranty does not include routine cleaning or 

periodic check-up. 

 

3.

 

Nemesis reserves the right to make changes in design and/or performance 

improvements upon its products without any obligation to include these changes in any 

products theretofore manufactured. 

 

4.

 

This is the only written warranty applicable to this product and supersedes all prior 

warranties and written descriptions of warranty terms and conditions heretofore 

published 

 

5.

 

Warranty is limited to 1 year from date of purchase. 

 

Activate Your Warranty: 

Send the following information to: 

[email protected]

 

Name/Company 

Product Model/Name 

Date of Purchase 

Where Purchased 

Physical Address 

Email Address

Activating your warranty signifies that you have read and understand the limited warranty listed above. 

YOU 

MUST ACTIVATE YOUR WARRANTY WITHIN TWO WEEKS OF THE PURCHASE DATE

 

Содержание Orochi

Страница 1: ...nemesisuvc com 469 466 2UVC support nemesisuvc com Orochi USER MANUAL English ...

Страница 2: ...g 9 Customer Support 9 Limited Warranty 10 Benefits of UV C Technology 11 UV C Disclaimer 11 General Guidelines 12 Technical Specifications 13 Fixture Overview 14 How do I use my Orochi 15 Timer Setup Recommended Times 17 Cleaning 18 Replacing Radiators 18 ...

Страница 3: ...k of personal injury Overexposure can result in damage to eyes and bare skin To reduce the risk of overexposure this equipment must be installed in accordance with the manufacturer s site planning recommendations This may include instructions on the relative location of each germicidal system component the minimum distances between UV generating devices and other objects or surfaces and protection...

Страница 4: ...ompletely dependent on types and quality of materials and if they have UV C protection built in The FDA approved waivers on UV A UV B and UV C more information is available from the FDA at https www fda gov media 136533 download For the proper safe and effective use of your device it is ESSENTIAL that the user follows all guidelines and instructions in this manual Proper installation and use is es...

Страница 5: ...t and unplug before performing any service or maintenance 4 Do not operate without proper electrical ground 5 To prevent the risk of severe or fatal electrical shock special precautions must be taken 6 Equipment is intended for indoor use only 7 Do not alter the construction or design Do not remove safety labels or devices 8 Do not use equipment for other than its intended purpose as described in ...

Страница 6: ...which may be exposed to direct or reflected germicidal ultraviolet rays 11 Do not operate equipment if the power cord and or plug are damaged or if any other damage to the unit is visible or suspected 12 Utility power must match power requirements listed on the unit label 13 Equipment should be protected from the elements and from temperatures below freezing 14 Do not exceed equipment s maximum ra...

Страница 7: ...ger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Caution used without the safety alert symbol indicates a potentiall...

Страница 8: ...afety labels Contact the factory to obtain replacement safety labels These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s pu...

Страница 9: ...d during shipping If the packaging appears damaged carefully inspect your unit If you find any damage contact customer support before attempting to operate your unit Contents Nemesis Orochi Power cable Manual ATTENTION Operator MUST READ ENTIRE MANUAL before attempting to operate the Tower Failure to follow instructions guidelines laid out in this manual will void the warranty and could lead to ph...

Страница 10: ...does not include routine cleaning or periodic check up 3 Nemesis reserves the right to make changes in design and or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured 4 This is the only written warranty applicable to this product and supersedes all prior warranties and written descriptions of warranty terms and condi...

Страница 11: ...products being sold pursuant to this Agreement must be installed correctly and used properly to be effective Nemesis is not responsible for improper installation usage or damages caused by the end user Nemesis makes no representations guarantees or assurances as to the final effectiveness of using a UV C lighting system for sanitization Nemesis warrants that with proper installation and usage scie...

Страница 12: ...ture from the skin can cause the coating on the radiator to deteriorate Take extreme care when replacing radiators Check all fixtures in the Orochi for dust and other contaminates monthly Cleaning can be done with a fresh dry lint free cloth or with an air compressor on very low psi See page 18 for more detailed instructions Take care when cleaning debris from broken radiators DO NOT dispose with ...

Страница 13: ...f UV C for disinfection of equipment of any kind Emits germicidal wavelength of 254nm Visual alerts during use Heavy duty case construction Utilizes 3 High Output Nemesis UV C radiators for efficient and effective disinfection Lamp Source TUV 55 W HO lamp technology Dimensions 42 x 16 x 13 Weight 45lbs Input voltage AC 120V 60Hz 2 amps 120v Rating Indoor use only ...

Страница 14: ...Nemesis Orochi V1 14 Fixture Overview Timer Control Panel Power Cable and Switch ...

Страница 15: ...ochi must be COMPLETELY closed in order for the Timer Control Panel to function Ensure there is power to the unit and that the doors are completely shut before attempting to set your timer Step 4 Once your timer is set insert the shelves as desired and place any items you would like to disinfect in the Orochi Step 5 Close the door and the Timer Control Panel will power back on Simply press Start G...

Страница 16: ... 0 999s Accuracy 1s P0 2 Timing time mode 0 999min Accuracy 1min P0 3 Timing time mode 0 999h Accuracy 1h P1 0 Relay will ON after delay T1 P1 1 Relay will OFF after delay T1 P1 2 Relay will ON after delay T1 Then Relay will OFF after delay P1 3 Relay will OFF after delay T1 Then Relay will ON after delay T2 Then Stop P1 4 Relay will ON after delay T1 Then Relay will OFF after delay T2 Then cycle ...

Страница 17: ...onds P0 is set at 1 and P1 is set at 2 It is set so that T1 is the start delay and T2 is the disinfection time Once the countdown completes the UV C lamps will power off and the Timer will reset Recommended Timings 180s Extreme Clean 120s Deep Clean 60s Standard Clean 30s Quick Clean NOTE If the door of the Orochi is opened during operation the Timer Control Panel will lose power and the UV C radi...

Страница 18: ...are hands oils from the skin will deteriorate the coating on the outside of the glass use sterile gloves and eye protection when working with radiators Twist both ends of the radiator turn to unlock the radiator from the socket you will hear a click Carefully remove the old radiator Place one end of the new radiator into the socket gently apply pressure to depress the socket and allow the other en...

Страница 19: ...Nemesis Orochi V1 19 User Manual Version 1 Updated 03 22 2021 www nemesisuvc com 469 466 2UVC ...