Doc. No. : WL10-0001
Revision No.: 1.0
Version: 10.0
20.09.2016
5
EN
Installation
1. Please use the screw to install the smoke alarm according to the pictures below.
2. Use the two pieces of screw (accessories of the detector) to fix the mounting plate in
the roof.
3. Fix the hamulus of the mounting plate into the hamulus hole of the detector and turn deasil.
Hamulus
hole
Hamulus
hole
Screw
hole
Screw
hole
Hamulus
Hamulus
Notes
1. Battery types approved with this domestic smoke alarm:
• Forte ER9V
• Fanso ER9V
and 3x 1.5V battery
• Pair Deer 3x 1.5V LR6/AA
• GP 3x 1.5V GP15AU
• Mustang 3x 1.5V LR6/AA
2. The radio link functionality is not included within the scope of approval.
Technical Parameter
Working voltage:
DC9V (smoke testing)
DC4.5V (transmission / Receiver: 3pcs 1.5V battery)
Current:
DC9V quiescent current ≤ 10uA
DC9V alarm current ≤ 20mA
DC4.5V quiescent current ≤ 230uA
DC4.5V working current ≤ 4mA
Alarming decibel:
≥ 85dB / 3m
Alarming-LED:
Red LED
Learn-LED:
Red / green LED
Frequency:
433.92 MHz
Transmission / Receiver distance: Spacious distance ≤ 60m
Working temperature:
-10~40