XR-PM – POLE MOUNT INSTALLATION
Refer to alternate instructions if using Conduit, Hook, Wall or Yoke Mount
INSTALLATION STEPS
Step 3
STEP 1.
Inspect shipping package and contents to ensure no damage has
occurred during shipping.
STEP 2.
Install the provided plastic 3/4” bushing into side 3/4" NPT entry.
STEP 3.
Install Pole Mount and gasket with adhesive side applied to mount
using included M6 bolts and washers.
Torque to 5 Nm (45 in-lbs)
STEP 4.
Thread luminaire assembly onto 1.5” NPT pole.
NOTE:
To aid in assembly and provide protection against ingress, use of a petrolatum
or soap thickened mineral oil based thread lubricant/sealant is necessary.
Un-used conduit opening must be plugged to maintain the integrity of the
enclosure.
STEP 5.
Insert and tension M6 set screw to pole to lock rotation.
STEP 6.
Resume installation instructions provided with luminaire. (STEP 4 in XR
Installation Instructions from the Surface/Ceiling Mount installation
provided with Luminaire).
SET SCREW
This XR-PM kit is intended for use with UL Listed XR luminaire as
marked on the luminaire nameplate.
Accessory Package Contents
XR-PM
PART NAME
QTY
1
1
4
4
1
1
POLE MOUNT
POLE MOUNT GASKET
M6 X 25mm HEX HEAD CAP SCREW
M6 FLAT WASHER
M6 X 16mm HEX HEAD CAP SCREW
3/4 NPT THREADED SMOOTH BORE BUSHING
TM
Nemalux
I N D U S T R I A L
XR-GEN
rev. A-13
5-14
www.nemalux.com | [email protected] | Tel 403•242•7475 | Fax 403•243•6190
MADE IN CANADA