background image

XR-YK – HIGH VIBRATION YOKE INSTALLATION

Refer to alternate instructions if using Conduit, Hook, Pole, Wall Mount, or Yoke Mount

STEP 1.

Inspect shipping package and contents to ensure no damage has 

occurred during shipping. 

STEP 2. 

Mount XR high vibration yoke to mounting surface using a minimum of 

4x ¼-20 or M6 fasteners (not provided).

STEP 3.

Make wiring connections from branch circuit conductors to factory 

provided lead wires using one of the 3/4" NPT threaded entries. Follow 

wiring method requirements of the Canadian Electrical Code or 

National Electrical Code for the installation.

NOTE:

To aid in assembly and protection against ingress use of a petrolatum or soap 

thickened mineral oil based thread lubricant/sealant is necessary.

Un-used conduit opening must be plugged to maintain the integrity of the 

enclosure.

STEP 4.

Mount XR Cheek Plates to sides of XR luminaire using 4x M6 flat head 

cap screws per side. Thread one cheek plate over installed wiring 

during assembly. Torque fasteners to 5 Nm (45 in-lbs).

STEP 5. 

Thread installed wiring through opening in XR high vibration yoke 

mount and install XR luminaire into yoke. The raised circular bosses on 

the XR cheek plates should register inside of the large circular holes on 

the XR high vibration yoke mount arms. Rotate luminaire to aim in the 

desired direction and fasten in place using 2x M6 socket head cap 

screws and flat washers per side. Torque fasteners to 5 Nm (45 in-lbs).

STEP 6.

Resume installation instructions provided with luminaire. (STEP 4 in XR 

Installation Instructions from the Surface/Ceiling Mount installation 

provided with Luminaire).

Step 4

Step 2

This XR-YK kit is intended for use with UL Listed XR luminaire as 

marked on the luminaire nameplate.  

Accessory Package Contents

INSTALLATION STEPS

XR-YK

PART NAME

QTY

1

2

8

4

4

XR HIGH VIBRATION YOKE

CHEEK PLATE

M6 x 1 x 25mm SOCKET FLAT HEAD CAP SCREW

M6 FLAT WASHER

M6 x 1 x 16mm SOCKET HEAD CAP SCREW

TM

Nemalux

I N D U S T R I A L

XR-GEN

rev. A-13

7-14

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

8.0in

4.3in

  203mm  

  108mm  

3.8in

  95mm   

2.3in

  59mm   

10 x   7mm 0.3in  THRU ALL

Содержание XR-GEN Series

Страница 1: ...Class 1 Wiring only All supply field wiring must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Ambient Temperature Range XR8 50 C to 75 C XR10 50 C to...

Страница 2: ...via retention strap Note Screws are captive fasteners and will remain attached to the cover for ease of reinstall and to prevent loss of fasteners 5 0in 126mm 5 2in 132mm 16 0in 405mm 17 3in 441mm 0...

Страница 3: ...0 A for control needs 0 10V Controller must sink current from LED driver 0 10V control connections NOTE To aid in assembly and provide protection against ingress use of a petrolatum or soap thickened...

Страница 4: ...REEN VIOLET GREY TM Nemalux I N D U S T R I A L XR GEN rev A 13 4 14 www nemalux com sales nemalux com Tel 403 242 7475 Fax 403 243 6190 MADE IN CANADA Any additional wiring not shown has been capped...

Страница 5: ...ead lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 5 Insert and tension M6 set screw to pole to lock rotation STEP 6 Resume inst...

Страница 6: ...ly gasket to mount with adhesive backed side Torque to 5 Nm 45 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backed gasket Apply gasket with adhesive side applied to...

Страница 7: ...assembly Torque fasteners to 5 Nm 45 in lbs STEP 5 Thread installed wiring through opening in XR high vibration yoke mount and install XR luminaire into yoke The raised circular bosses on the XR cheek...

Страница 8: ...curved slot the luminaire may be configured for an upward or downward adjustable swing STEP 4 Thread installed wiring through openings in yoke mount cheek plate and yoke mount bracket Mount yoke asse...

Страница 9: ...ly and provide protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrit...

Страница 10: ...n through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Install remaining loop of secondary safety chain or steel cable to suit...

Страница 11: ...dy near AC input Secure the surge protector and driver lead wires together as close to the origin of the driver lead wires as possible using the provided zip tie STEP 4 Wire according to wiring instru...

Страница 12: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Страница 13: ...provided zip tie STEP 4 Wire according to wiring instructions on Page 12 14 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close XR Wiring Cover Ensure the retention cable is...

Страница 14: ...t conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GRO...

Отзывы: