IP66 & IP67

110V-254V AC or 18-48V AC/18-69V DC 

Compliance with the Essential Health and Safety Requirements has been assessed by 

reference to the following standards -   

EN 60079-0 : 2018 

EN 60079-7: 2015+A1:2018  

EN 60079-31 : 2014

EN 60079-18:2015+A1:2017 

And also 2014/35/EU – Low Voltage Directive, 2014/30/EU – EMC Directive

Signed

  

Name

 

Barry Thompson 

Position 

Director

Dated

Serial number

CML16ATEX1130 or IEC Ex CML16.0052 or CML21UKEX1100

Standard variants

II 2 D Ex tb IIIC T80°C Db

-40°C to +60°C

Emergency variants

II 2 D Ex tb IIIC T76°C Db 

-20°C to +50°C

Содержание RL Series

Страница 1: ...ct Nemalux for immediate assistance and advice Linear Range Installation Guide CML14ATEX3119 IEC Ex CML 15 0001 CML21UKEX3105 CML15ATEX4138 IEC Ex CML15 0068 CML21UKEX4104 CML16ATEX1130 IEC Ex CML16 0...

Страница 2: ...compound to screw threads such as PSU cover and external earth points During installation ensure exterior surface of the product is not in direct contact with a dissimilar metal such as galvanised st...

Страница 3: ...lux for further details The spigot mount version of the product is provided with a pole mount system and 2xM6 A4 SS Grub Screws for mounting onto 32 43mm diameter poles Once mounted tighten grub screw...

Страница 4: ...h the unit separately an internal and external earth point are provided as standard at each end of the luminaire 5 Connect wires to mains supply 6 If the unit is opened for any reason disconnect mains...

Страница 5: ...ated in the compartment that contains the battery the fuse is disconnectedafterfinalmanufacturingtesting Wheninstallingthelinearthebatteryfuse will need to be reconnected and the unit charged for 24 h...

Страница 6: ...arried out at a random time every 3 months Checks the battery s capacity and lamp s condition Performs self recovery for the battery if not at peak capacity Is carried out at 100 load Discharges only...

Страница 7: ...isolated connected when a hazardous environment is NOT present prior to carrying out any maintenance work 5 The unit has either 1 or 2 independent power supplies located in the terminal chamber covers...

Страница 8: ...Mains Frequency 50 60Hz Inrush Current Ipeak 50 20A t 300 s 28A t 300 s Total Harmonic Distortion 230Vac full load 10 IP Rating IP66 67 Weight std 6Kg 7Kg 9Kg 10Kg Dimensions See previous pages for l...

Страница 9: ...1 EM RL 2 STD RL 2 EM B 10A 11 10 5 4 B 16A 17 15 8 7 B 20A 25 22 12 11 B 25A 35 32 16 15 C 10A 24 20 11 10 C 16A 34 28 16 15 C 20A 49 44 23 20 C 25A 58 55 28 25 9 12 www nemalux com sales nemalux co...

Страница 10: ...80 C Db 40 C to 60 C Standard variants II 3 GD Ex ec mc IIC T4 Gc Ex tc IIIC T80 C Dc 40 C to 60 C Emergency variants II 2 GD Ex eb mb IIC T4 Gb Ex tb IIIC T76 C Db 20 C to 50 C Emergency variants II...

Страница 11: ...assessed by reference to the following standards EN 60079 0 2018 EN 60079 7 2015 A1 2018 EN 60079 31 2014 EN 60079 18 2015 A1 2017 And also 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive S...