Stud welding unit N1500i
Version 1.31 7.June.2013
Manual part number: 729-110-027
29
Nelson Stud Welding, Inc. • 7900 West Ridge Road • Elyria, Ohio 44035 • USA
Firmware version 1.06
F code
Description
Possible Values
Default
Unit
Notes
F0
Language
ENGLISH,GERMAN
,
ITALIAN,
SPANISH, FRENCH,
POLISH
ENGLISH
x
F1
Error Display
E--- to E018
E---
x
F2
Plunge Short Circuit
On-Time
0 to 150
80
ms
When short cycle mode is enabled, this defaults to
20ms. When disabled, this defaults to 80ms for 2-
wire gun interface, 20ms for 4-wire gun interface.
F3
Stud Expert Mode
Easy Access
POSTION, MATERIAL,
PROCESS
POSITION
x
F4
Stud Expert Mode
Position
DOWNHAND, VERTICAL,
OVERHEAD
DOWN HAND
x
F5
Stud Expert Mode
Material
MILD STEEL, STAINLESS
STEEL, ALUMINUM
MILD STEEL
x
F6
Stud Expert Mode
Process
STUD WELD
STUD WELD
x
F7
Calibration Values
700 to 850
750
Clock
cycles
Used by manufacturing. Do not change
F8
Chuck Saver
OFF ON
ON
x
F9
Gas Enable
OFF ON
OFF
x
F10
Gas Preflow Time
10 to 2000
500
ms
F11
Gas Postflow Time
10 to 2000
500
ms
F12
Stud Feed Enable
OFF ON
OFF
x
This automatically turns on ‘short cycle mode’ when
enabled. Disabling it does not disable ‘short cycle
mode’.
F13
Stud Feed Time
10 to 2000
50
ms
Pulse width of stud feed signal. This only applies
when stud feed is enabled.
F14
Stud Feed Normal Level
NORMAL CLOSED,
NORMAL OPEN
NORMAL OPEN
x
This only applies when stud feed is enabled.
F15
Stud Feed Style
AFTER CONTACT BREAK,
AFTER WELD
AFTER CONTACT
BREAK
x
When to get the signal. This only applies when stud
feed is enabled.