Stud welding unit N1500i
Version 1.31 7.June.2013
Manual part number: 729-110-027
7
Nelson Stud
Welding, Inc. • 7900 West Ridge Road • Elyria, Ohio 44035 • USA
Warning!
Connect the earth ground cable plug into the proper socket of the
Nelweld N1500i.
The connection must be secured by a full “turn to the right” of
the earth ground cable plug!
1.2.6
Connection of the Ground Cable
The welding current return takes place via the earth ground cable,
which must be connected as follows to the earth ground cable socket
of the Nelweld N1500i.
Earth ground Cable Connection (X3)
Use cable resistance monitor (see section 3.15) to continuously monitor loose
connector fault condition in production.
1.2.7
Connection of the workpiece
When connecting the earth ground terminals attention must be paid to
the following:
1.
The earth ground terminals must be connected directly to the
workpiece or to the workpiece fixture (welding bench, welding
grid).
Steel constructions, tracks, pipelines, etc. may not be used as current
conductors, unless they are themselves the workpiece to be welded.
2.
The welding current circuit may not be earth grounded.
Exception: The workpiece itself or the workpiece fixture are earth
grounded compulsorily (pipelines, shipbuilding, etc.).
3.
Place the earth ground terminals if possible at the same distance
from the point of welding when two ground clamps are used.
Note!