Nelsen Water Solutions User Guide

When the system is operating, one of five displays 
may be shown. Pressing 

NEXT

 will alternate 

between the displays shown below.

User 1

Typical user display shows 

Time of Day and droplet of 

water indicating water flow. 

User 2

Shows volume remaining 

to regeneration. This screen 

will not be viewed if the 

control is set for time-clock 

operation.

User 3

Displays number of days 

to next regeneration. Not 

shown when day override 

set to off.

User Displays

TIME OF DAY

12:01

PM 

CAPACITY REMAINING

1200

GAL

REGENERATION IN

14 DAYS

User 4

Flow Rate displays the 

current flow rate of treated 

water through the valve. If 

Configuration 3CS is set  to 

ALT A or B and the valve 

is in Standby, this display 

and the flashing Flow Indicator viewed in other User 

Screens will not be viewed.
A Tank In Service Indicator (A or B) is active 

whenever 1.0T Mode is set in Configuration 2CS.

User 5

Displays dealer contact 

name and number when 

programmed in the Installer 

Level. Steps 7IL & 8IL.

FLOW RATE

  A        0.0

GPM

PPPPPPPPPPPPPPPPPP

NNNNNNN

TEL

Содержание Signature AIO

Страница 1: ...Signature Series User Guide Softeners Filters 1 1 1 4 1 1 2 2 Twin Control Valves Signature Series Single Tank AIO Twin Tank ...

Страница 2: ...D RINSE FILL is displayed whenever a zero capacity tank has transferred to an off line state and is currently waiting to initiate the second portion of a regeneration cycle Viewed only when Delayed Rinse and Fill is set to ON Regen Error Screens BACKWASH 6 36 MIN 2 REGEN PENDING ALT MAV STAND BY AUX MAV DELAYED RINSE FILL PENDING Error Screens ERROR Screen displays when an error occurs and no Deal...

Страница 3: ...ayed Holding NEXT and REGEN simultaneously for 3 seconds initiates a control reset The software version is displayed and the piston returns to the home service position re synchronizing the valve Used with a twin valve 1 0T holding for at least 3 seconds causes a switch in the tank in Service without cycling the regeneration valve After tank switch days remaining and capacity remaining status is r...

Страница 4: ...neration Not shown when day override set to off User Displays TIME OF DAY 12 01 PM CAPACITY REMAINING 1200GAL REGENERATION IN 14DAYS User 4 Flow Rate displays the current flow rate of treated water through the valve If Configuration 3CS is set to ALT A or B and the valve is in Standby this display and the flashing Flow Indicator viewed in other User Screens will not be viewed A Tank In Service Ind...

Страница 5: ...ne Tank Control Valve Softener Tank Safety Brine Valve Air Check Ion Exchange Resin Distributor Riser Tube Distributor Riser Tube Distributor Basket Distributor Basket Single Tank Softener Air Injection Oxidation AIO Filter System Control Valve Softener Tank Safety Brine Valve Air Check Distributor Basket Brine Tank Twin Tank Softener ...

Страница 6: ...spect the brine tank at least once a year for buildup of insoluble materials It is recommended to periodically clean the brine tank no matter what salt you use REMEMBER Salt is the fuel to run your water conditioner Buy the best clean salt available Operating Conditions Your water conditioner has been designed to adequately handle up to 100 grains per gallon of hardness and up to 2 ppm of ferrous ...

Страница 7: ...t five minutes for the board to de energize 4 With the battery out re connect the power supply to the board The board s display should begin to show information This indicates that the board is operating correctly If the display does not work call installing dealer for service 5 To replace with a new battery unplug the transformer from the outlet Install a 3 volt Lithium Coin Cell type 2032 batter...

Страница 8: ...M memory 405 HISTORY MEMORY Control continues to operate normally w check sum error for the History Section of E2 PROM memory however error is recorded in Error Log 406 CONTACT MEMORY Control can no longer operate properly due to a check sum error for the Contact Screen Section of E2 PROM memory 407 STATUS RAM STATUS RAM MEMORY FAILURE Error generated when the microcontroller can t operate properl...

Страница 9: ...res are installed securely into three pin connector labeled METER Defective meter Replace meter Defective PC Board Replace PC Board Control valve regenerates at wrong time of day Power outage Reset time of day If PC Board has battery back up present the battery may be depleted See front cover and drive assembly drawing for instructions Time of day is not set correctly Reset to correct time of day ...

Страница 10: ...size Replace injector with correct size for the application Restricted drain line Check drain line for restrictions or debris and clean Excessive water in brine tank Improper program settings Check refill setting Plugged injector Remove injector and clean or replace Drive cap assembly not tightened in properly Re tighten the drive cap assembly Damaged seal stack assembly Replace seal stack Restric...

Страница 11: ...ential purposes in a single family dwelling This limited warranty shall be null and void if the Product is used for commercial industrial or other non residential applications This Limited Warranty will not cover any Product used for outdoor installations unless a weather cover that complies with manufacturer requirements is utilized This Limited Warranty shall not cover the Product if operated at...

Страница 12: ...HE TERMS HEREOF TO THE EXTENT A WAIVER OF IMPLIED WARRANTIES IS PROHIBITED BY LAW ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE DURATION OF ANY WRITTEN WARRANTY PROVIDED BY NELSEN IN NO EVENT SHALL NELSEN BE LIABLE TO BUYER OR TO ANY THIRD PARTY FOR CONSEQUENTIAL INCIDENTAL SPECIAL OR PUNITIVE DAMAGES OR FOR LOST PROFITS OR LOSS OF USE RESULTING FROM OR IN ANY MANNER RELATED TO THE PRODUCT ITS DE...

Отзывы: