3
Initial Cartridge Installation
1 Remove cap from cartridge tank (see Removal of
Cartridge, steps 1-3) and then push top cap down
equally with both hands to unseat retaining ring.
Remove ring from
groove by carefully
grasping handle and
pulling inward then
upward. Ring will
slide completely out
of groove.
(Photos A & B)
2 Remove top of cap
from system by
lifting up on top
handles (Photo C).
3 Remove plastic
covering
surrounding filter
cartridge and
discard.
4 Lubricate O-rings on
cartridge to ensure
proper sealing. Do
not use pipe dope,
Vaseline, oils or
other unacceptable
lubricants on
O-rings. Food grade
silicone lubricant is
recommended.
5 Insert cartridge
into bottom center
of tank, assuring
proper seal and
alignment by
pushing down
gently until fully
seated (Photo D).
6 Attach product
description tag
(right) to retain-
ing ring handle
for future
reference
(Photo E).
NOTE:
This tag is
found on the new
cartridge handle.
7 Replace top cap
of tank using top
handles.
8 Push top cap down to make room for placement of
retaining ring in ring groove.
9 Insert retaining ring
into ring groove,
starting at the end
opposite of the
handle. Using only
hands, gently push
retaining ring into
groove until entire
ring is in place and
both ends meet in groove section (Photo F).
10 To ensure proper engagement, hold retaining ring by
handle and slightly rotate around inner diameter of
vessel.
11 Slowly turn water supply on to system by first
opening inlet valve and pressing red depressurization
valve to completely vent tank of trapped air; when
water leaks out of depressurization valve, stop
pushing and open outlet valve.
12 Check system for leaks and ensure system integrity.
orange
DATE OF INSTALL:
DESCRIPTION:
50x20 Micron
Double Pleat Cartridge
Serial#: OR
oneFiltration.com
3