Nelsen Corporation NFS-HF Скачать руководство пользователя страница 5

3

Initial Cartridge Installation

1    Remove cap from cartridge tank (see Removal of 

Cartridge, steps 1-3) and then push top cap down 
equally with both hands to unseat retaining ring. 
Remove ring from 
groove by carefully 
grasping handle and 
pulling inward then 
upward. Ring will 
slide completely out 
of groove.  
(Photos A & B)

2   Remove top of cap 

from system by 
lifting up on top 
handles (Photo C).

3      Remove  plastic 

covering 
surrounding filter 
cartridge and 
discard.

4     Lubricate O-rings on 

cartridge to ensure 
proper sealing. Do 
not use pipe dope, 
Vaseline, oils or 
other unacceptable 
lubricants on 
O-rings. Food grade 
silicone lubricant is 
recommended.

5      Insert  cartridge 

into bottom center 
of tank, assuring 
proper seal and 
alignment by 
pushing down 
gently until fully 
seated (Photo D).

6      Attach  product   

description tag  
(right) to retain- 
ing ring handle  
for future  
reference  
(Photo E).

  NOTE:

  

This tag is  

  found on the new  
  cartridge handle.

7   Replace top cap 

of tank using top 
handles.

8   Push top cap down to make room for placement of 

retaining ring in ring groove.

9   Insert retaining ring 

into ring groove, 
starting at the end 
opposite of the 
handle. Using only 
hands, gently push 
retaining ring into 
groove until entire 
ring is in place and 
both ends meet in groove section (Photo F).

10   To ensure proper engagement, hold retaining ring by 

handle and slightly rotate around inner diameter of 
vessel.

11   Slowly turn water supply on to system by first 

opening inlet valve and pressing red depressurization 
valve to completely vent tank of trapped air; when 
water leaks out of depressurization valve, stop 
pushing and open outlet valve.

12    Check system for leaks and ensure system integrity.

orange

DATE OF INSTALL:

DESCRIPTION:

50x20 Micron
Double Pleat Cartridge

Serial#: OR

        oneFiltration.com

3

Содержание NFS-HF

Страница 1: ...Installation Maintenance Manual Nelsen Filtration Cartridge Systems NFS HF Residential Light Commercial Cartridge Tank System NFS HF PLUS Commercial Cartridge Tank System ...

Страница 2: ...erein applies only when used within the product specifications and service life from the date of installation beyond which ENPRESS LLC is absolved of any and all liability for any use of the product There are no other warranties either of merchantability or fitness either expressed or implied This warranty gives you specific legal rights and you may also have other rights which vary from state to ...

Страница 3: ...application provisions should be made so that the system is located close to a drain Also make sure the installation site has enough overhead clearance for installation and replacement of the cartridges Orientation of the system may be vertical or horizontal which ever fits the site application An optional bottom drain is available for these cartridge filter systems to allow rinsing of the cartrid...

Страница 4: ... cartridge Closing inlet and outlet valve and opening drain will relieve pressure on filter tank for cartridge replacement Provisions should be made to install three 90 degree ball valves to create a bypass to the cartridge filter tank Because of the pipe size this will need to be created on the job site Any piping materials may be used however be sure to observe local plumbing codes These ball va...

Страница 5: ...product description tag right to retain ing ring handle for future reference Photo E NOTE This tag is found on the new cartridge handle 7 Replace top cap of tank using top handles 8 Push top cap down to make room for placement of retaining ring in ring groove 9 Insert retaining ring into ring groove starting at the end opposite of the handle Using only hands gently push retaining ring into groove ...

Страница 6: ...sping handle and pulling upward while holding the tank down Photo E The old cartridge may be extremely heavy with sediment water weight Place in bag and dispose of in accordance with local state and federal laws and regulations 8 If necessary open drain and flush system further with a bucket of water to remove final sediment and particles Once flushed close drain line 9 Open cold water faucet near...

Страница 7: ...FS 2005 SWMB HF 20x5 Micron String w Meltblown PP Core NFS 5020 SWMB HF 50x20 Micron String w Meltblown PP Core Carbon Block Cartridge Blue Series NFS 03 CB HF 3 Micron Carbon Block High Capacity NFS 20 CB HF 20 Micron High Porosity Low Pres Drop Pleated Polypropylene Commercial Plus Systems Red Series NFS P1A PLUS 1 Micron Absolute Pleated PP NFS P05 PLUS 5 Micron Absolute Pleated PP NFS P10 PLUS...

Страница 8: ...CT 2 5IC HF Filtration Tank Inlet Cap 2 1 2 ENCT 2 5 ADAPTOR HF Filtration Tank Adaptor 2 1 2 ENCT DRAIN1 1 4 HF Filtration Tank Drain 1 1 4 Commercial Plus System Bottom of Tank ENCT 4 5IC HF PLUS Filtration Tank Inlet Cap 4 1 2 ENCT 4 5 ADAPTOR HF PLUS Filtration Tank Adaptor 4 1 2 ENCT DRAIN2 HF PLUS Filtration Tank Drain 2 System Components A D G B E H C F J 2013 Nelsen Corporation NFS MANUAL ...