background image

-8-

  3)   Turn off feed water valve and tank valve and set 

tank aside (15 minutes min).

D. Install the Drain Connection

 

NOTE:   

For Basement Installation See Figure 6, 

Page 16.

Under counter Installations:

 

IMPORTANT:

  

 Before  starting  this  pro ce dure,   

inspect the condition of the drain 

piping, especially in older homes 

where the traps and tailpieces can  

be deceptively thin and frail. If in 

poor condition, the condition  

should be remedied.

The drain saddle assembly is de signed to fit around a 

standard 1-1/2" OD drain pipe.

The drain saddle should always be installed above 

(before) the trap and on the vertical or horizontal 

tailpiece. Never in stall the drain saddle close to the 

outlet of a gar bage disposal or plugging of the RO drain 

line may occur. See Figure 4.

  
  

  1)   Position threaded half of drain saddle at selected  

lo ca tion and mark the spot through the opening. 

See diagram.

  2)   Drill a 1/4" hole at the marked spot through one 

side of drain tail piece.

  3)   Position both halves of drain sad dle on drain pipe 

so thread ed opening lines up with the hole in  

drain pipe.

  4)   Use bolts and nuts to clamp drain saddle onto 

drain pipe. Do not over tight en and make sure 

there is equal space between saddle halves on 

each side. See diagram.

  5)   Wrap teflon tape on thread of “John Guest” fitting 

and tighten into drain sad dle.

E.  Make Initial Tubing Connections

 NOTE:

   

 For Basement Installation See Figure 6, 

Page 16.

  Under counter Installation:

  1)   It is advantageous to make some of the tubing 

con nec tions at this time, since the under-sink 

work area is not so cramped and access to the 

com po nents is easier. If nec es sary, refer to the  

enclosed diagram on use of the “John Guest” 

plastic fittings.

  2)   The orange 3/8" tubing should already have been 

con nect ed to the feed water valve with a 3/8" 

brass com pres sion nut, in sert and plastic sleeve.

  3)   Tighten 3/8" plastic “John Guest” fitting onto 

threaded faucet nipple. No Teflon tape is required 

to make an ef fec tive seal. It may be necessary to 

hold faucet from turning while tightening fit ting.

  4)   Route black 3/8" tubing from faucet air gap to 

drain saddle so that it slopes con tin u ous ly down-

ward with out loops or low spots. Cut to proper 

length and con nect to “John Guest” drain fitting.

F.   Install the Purification Assembly &  

Storage Assembly

 NOTE:

   

 For Basement Installation See Figure 6, 

Page 16.

Under counter Installation:

The purification assembly is usually mounted to the 

right or left sink cabinet sidewall, taking into con sid er-

ation the space available and the tank lo ca tion. Gener-

ally, the tank is placed in the rear of the cabinet while 

Drain Pipe

Drain Clamp

Front Plate

“John Guest”

Locking Clip

1/4" Screw

1/4" Nut

“John Guest” 

Fitting

1/4" Drilled Hole

  

FIGURE 4 

 

 

Feed Valve Installation

Nelsen

 

Corporation

Содержание Aqua Classic

Страница 1: ...Reverse Osmosis Drinking Water Sys tems Installation Operation Service Manual Including Systems with optional ECF Module...

Страница 2: ......

Страница 3: ...lved Solids T D S In the Reverse Osmosis process dissolved min er als are sep a rat ed from the incoming water Feed Wa ter to pro duce the product water the Permeate The excess minerals are rinsed to...

Страница 4: ...CT 3 8 Blue DRAIN CLAMP locate above P trap Holding Tank Shutoff Valve open position TANK 3 8 Yellow REVERSE OSMOSIS ASSEMBLY NOTE Aqua Classic II and Aqua Elite II R O Systems include a third filter...

Страница 5: ...Low range air pressure gauge 19 Bicycle hand air pump 20 Small bottle of liquid chlorine bleach 21 Graduated measuring cylinder 22 Assorted clean up materials C Determine System Location The applianc...

Страница 6: ...ce for Installation Open shipping carton and remove com po nents Check that all installation parts are present which includes the purification assembly storage tank faucet installation hardware and tu...

Страница 7: ...e a suitable hole for the RO faucet A pipe cap or plug will be required to seal the sprayer connection 1 Make The Faucet Mounting Hole IMPORTANT It is mandatory that safety glass es be worn during sin...

Страница 8: ...does not touch out er rim of the cut porce lain enamel Con tin ue with this bit to cut through metal until sink has been completely penetrated IMPORTANT When using a porcelain cutter it is critical t...

Страница 9: ...o prevent shock hazard use a battery op er at ed drill 3 Before installing saddle tapping valve make sure pierc ing lance does not protrude be yond rubber gasket 4 Assemble saddle tapping valve on cop...

Страница 10: ...and tighten into drain sad dle E Make Initial Tubing Connections NOTE For Basement Installation See Figure 6 Page 16 Under counter Installation 1 It is advantageous to make some of the tubing con nec...

Страница 11: ...water valve to the Feed connection on purification as sem bly 2 Connect yellow 3 8 tubing from purification as sem bly to tank 3 Remove RED plug from drain elbow insert end of red 1 4 tubing leading...

Страница 12: ...y flush excess TDS from the new Carbon Post Filter before the green light will show K Clean Up Paperwork 1 Clean up the work thoroughly 2 Affix any special decals or stickers Be sure to record the hou...

Страница 13: ...nect orange 3 8 tubing from feed water valve to Feed connection on purification assembly 2 Connect blue 3 8 tubing from faucet to the Faucet connection on purification assembly 3 Locate the yellow plu...

Страница 14: ...be open slowly open the Saddle Tapping Valve on the Feed Water Line f As soon as water begins to drip out of the Dis pens ing Faucet close the Faucet g Let the system stand for 15 minutes h At the en...

Страница 15: ...ing to atmospheric pressure Product water quality and quantity greatly de pend upon the Net Pressure Differential p across the R O Mem brane This pressure differential is a summation of the feed water...

Страница 16: ...toff Valve open position TANK 3 8 Yellow Tank Shut off Valve Reverse Osmosis Assembly Equipped with Booster Pump CARBON Post Filter Housing SEDIMENT Pre Filter Housing Optional Angle Stop Adapter Valv...

Страница 17: ...rating at 90 psi or 100 psi will increase production rate by 30 40 Membrane rejection rate is rated at 60 psi the same mem brane operating at 90 psi 100 psi will increase reject rate by 5 10 depending...

Страница 18: ...dule would appear on the top of the system The installation would be similar to that shown Self Piercing Saddle Valve cold water line only PRODUCT 3 8 Blue Holding Tank Shutoff Valve Open Position Dri...

Страница 19: ...h water supply Ion Symbol Rejection Aluminum Al 3 97 98 Ammonium NH4 85 95 Borate B4O2 2 30 50 Boron B 60 70 Bromide Br 93 96 Cadmium Cd 2 93 97 Calcium Ca 2 95 98 Chloride CI 92 98 Chromate CrO4 2 85...

Страница 20: ...plication physical damage or damage caused fire act of God freezing or hot water If the unit is altered by anyone other than Nelsen Corporation the warranty is void To obtain service A contact your lo...