English - 29
English
room temperature controlled regulation (RR)
weather dependent regulation without
room temperature compensation (WD)
weather dependent regulation with room
temperature compensation (WD + RTC)
for WD and WD + RTC, the outside
temperature will be displayed in the right
bottom corner of the display as well.
Installation type
The type of installation:
1. Radiators
2. Convectors
3.Thermostatic radiator valves in the living room
4. Only floor heating (no radiators or convectors)
To each type of installation, a special firing
characteristic is attached (starting point, end
point, room influence); refer to table 6-1.
Starting point
The desired CH water temperature at +20 °C.
This is called the starting point of the firing
characteristic.
End point
The desired CH water temperature at -10 °C.
This is called the end point of the firing
characteristic.
Room influence
A factor which indicates the influence of the
room temperature to the WD + RTC control.
Setting the temperature control
The settings described below are only applicable for weather dependent regulation
(with or without room temperature compensation).