26 - English
English
30˚C
0˚C
10˚C
20˚C
-10˚C
outside temperature
starting point
end point
CH w
ater temper
atur
e
45˚C
60˚C
75˚C
Setting the temperature control
6.
Setting the temperature control
6.1 Selecting a temperature control
The IRT 30 thermostat is suitable for 3 kinds of temperature
control:
- Room temperature controlled regulation (RR)
- Weather dependent regulation (WD)
- Weather dependent regulation with room temperature
compensation (WD + RTC)
Select one of these control before you continue. Chapter 3
describes the points of attention for making your choice.
You have selected room temperature controlled
regulation (RR)
Set the thermostat as follows:
1. Go the CH menu; refer to paragraph 6.2.
2. Set
room temperature controlled regulation
.
3. Leave the CH menu.
4. Continue with setting the hot water supply; refer to chapter 7.
You have selected weather dependent regulation
(WD or WD + RTC)
Set the thermostat as follows:
1. Go the CH menu; refer to paragraph 6.2.
Only change the settings mentioned below!
2. Set
weather dependent regulation
.
3. Select the correct
installation type
.
4. Leave the CH menu.
5. Wait for 3 or 4 hours.
Firing characteristic
The firing characteristic is a line which shows the temperature
of the CH water at a certain outside temperature.You can set
the firing characteristic with the help of 2 points:
- the desired water temperature at +20 °C outside
temperature; starting point
- the desired water temperature at -10 °C outside
temperature; end point