en
Troubleshooting
42
Fault
Cause and troubleshooting
"E:36 / -10"
▶
Remove any unapproved extensions from the water
hose. Connecting the appliance
The pump cap is not fully screwed in.
▶
Ensure that the pump cap is screwed in all the way
into the appliance. The handle on the pump cap
must be in a vertical position.
→
"Cleaning the drain pump", Page 39
"E:36 / -25 / -26"
Drain pump is blocked.
▶
"Cleaning the drain pump", Page 38
"E:10 / -00 / -10 /
-20"
The pump for the intelligent dosing system is blocked.
1.
Switch off the appliance.
2.
Clean the pump unit.
→
"Cleaning the detergent drawer", Page 36
3.
If this display appears again, call customer service.
→
Note:
You can start the washing programme if you de-
activate the intelligent dosing system and dose manu-
ally.
→
The water pressure is low.
No remedial action possible.
The filters in the water inflow are blocked.
▶
Clean the filters in the water inflow.
The tap is turned off.
▶
Turn on the tap.
The water inlet hose is kinked or jammed.
▶
Ensure that the water inlet hose is not kinked or
jammed.
The detergent drawer has not been pushed in as far
as it can go.
▶
Push the detergent drawer in as far as it will go.
The pump unit is not inserted.
1.
Insert the pump unit into the detergent drawer.
→
"Cleaning the detergent drawer", Page 36
2.
Push the detergent drawer in as far as it will go.
flashes.
The automatic voltage control system detects an un-
authorised voltage under-usage.
▶
No remedial action possible.
Note:
If the power supply is stable, the programme
continues to run as normal.