background image

Installation instructions

 en

19

19.10 Instructions for the air extraction

mode

For air extraction mode, a one-way flap should be in-

stalled.

Notes

¡

If a one-way flap is not included with the appliance,

one can be ordered from a specialist retailer.

¡

If the exhaust air is conveyed through the external

wall, a telescopic duct should be used.

19.11 Installation

Checking the wall

1.

Check whether the wall is horizontal and adequately

load-bearing.

The maximum weight of the appliance is 30 kg.

2.

Drill the hole depth in accordance with the length of

the screws.

3.

Use the enclosed screws and wall plugs.

The enclosed screws and wall plugs are suitable for

use with solid brickwork. Use suitable fixing material

for other structures, e.g. plasterboard, porous con-

crete, poroton bricks.

4.

Install the appliance with a fixing material which is

sufficiently stable and has been adjusted accord-

ingly for both the structural conditions and the

weight of the appliance.

5.

Check the cut-out area for existing cables of other

appliances.

Preparing the wall

1.

Observe the information on the installation situation.

→ 

Page 18

2.

Ensure that there are no electrical wires, gas pipes

or water pipes in the area where holes are to be

drilled.

3.

Cover the hob to prevent damage.

4.

Determine the position of the extractor hood and

lightly mark where the lower edge of the appliance

should be on the wall.

Determine the centre of the hob.

Comply with the safety clearances for the hob.

We recommend fitting the extractor hood in such a

way that the lower edge of the glass screen is in

line with the lower edges of the adjacent wall-hung

cabinets.

5.

To make the installation easier, apply and secure

the packaging section that is used as the template

to the line that is marked out.

6.

Mark the positions for the screws.

7.

For the installation with the flue cover, separate the

template along the marked cut line.

8.

Place the detached part at the required position.

Observe the entire length of the flue duct.

9.

Drill the 8 mm diameter holes to a depth of 80 mm

for the fastenings.

10.

Remove the template.

Installing the appliance bracket

1.

Screw on the appliance bracket for the extractor

hood hand-tight.

2.

Use a spirit level to align the appliance bracket hori-

zontally and screw it firmly in place.

3.

Screw the enclosed sleeves fully into the upper ap-

pliance bracket.

Содержание D98IPT2S0B

Страница 1: ...Extractor hood User manual and installation instructions D98IPT2S0 D98IPT2S0B D98IPT2Y5...

Страница 2: ...cooking vapour in private households and in enclosed spaces in a domestic environment up to an altitude of max 4000 m above sea level 1 3 Restriction on user group This appliance may be used by childr...

Страница 3: ...ot let children play with small parts WARNING Risk of poisoning Risk of poisoning from flue gases being drawn back in Room air dependent heat pro ducing appliances e g gas oil wood or coal operated he...

Страница 4: ...isk of electric shock If the appliance or the power cord is dam aged this is dangerous Never operate a damaged appliance Never pull on the power cord to unplug the appliance Always unplug the applianc...

Страница 5: ...n speed in good time The odours are distributed around the room less Switch off the lighting if it is no longer required When the lighting is switched off it does not con sume any energy Clean or repl...

Страница 6: ...the filter saturation indicator Switching the appliance on or off Home Connect Selecting the favourites function Switching on fan setting 1 Switching on fan setting 2 Switching on fan setting 3 Switch...

Страница 7: ...pending on the setting of the sensor sensit ivity the optimum fan setting is automatically switched on You can change the sensor sensitivity setting in the Home Connect app Factory setting 3 Lowest se...

Страница 8: ...and is used to dry the odour filter after the cooking process 8 7 Interval ventilation In order to regularly ventilate your kitchen you can use the interval ventilation With interval ventilation the v...

Страница 9: ...act them have your ap pliance connected to the Home Connect server and if Remote Diagnostics is available in the country in which you are using the appliance Tip For further information and details ab...

Страница 10: ...lectric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance WARNING Risk of burns The appliance becom...

Страница 11: ...grease filter Page 10 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filte...

Страница 12: ...y a It may take a few minutes until all of the functions are available General malfunctions occur A software update may be required Update the software Software update Page 9 Di s pos al 13 Disposal 1...

Страница 13: ...Plus air recircu lation set Z51BII1X6 Clean Air Plus recircula tion kit flue free angled extractor hood Z51BIV1X6 Accessories Order number Long Life recirculation kit flue free angled ex tractor hood...

Страница 14: ...sger te GmbH Carl Wery Str 34 81739 Munich Germany The source code will be made available to you on re quest Please send your request to ossrequest bshg com or BSH Hausger te GmbH Carl Wery Str 34 817...

Страница 15: ...n instructions en 15 19 2 Included with the appliance After unpacking all parts check for any damage in transit and completeness of the delivery 19 3 Dimensions You will find the dimensions of the app...

Страница 16: ...eric pressure Toxic gases from the chimney or the extrac tion shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air...

Страница 17: ...tall unit an upper cabinet or a wall The dis tance between the appliance and the tall cabinet an upper cabinet or the wall must be at least 50 mm WARNING Risk of injury Components inside the appliance...

Страница 18: ...for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallatio...

Страница 19: ...n the installation situation Page 18 2 Ensure that there are no electrical wires gas pipes or water pipes in the area where holes are to be drilled 3 Cover the hob to prevent damage 4 Determine the po...

Страница 20: ...ight of the appliance from above using a screw driver 5 Secure the appliance from above using 2 nuts 6 Note Do not knock the gas pressure dampers against the painted inner frame Clip the gas pressure...

Страница 21: ...onnection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Installing the flue duct WARNING Risk...

Страница 22: ...e design profiles observe the enclosed in structions for the accessory Removing the appliance Note The design profiles are not hand grip elements Do not lift the appliance by the design profiles 1 Rem...

Страница 23: ......

Страница 24: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001809512 9001809512 031019 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Отзывы: