background image

en 

Installation instructions

18

Improper repairs are dangerous.

Repairs to the appliance should only be

carried out by trained specialist staff.

Only use genuine spare parts when repair-

ing the appliance.

If the power cord of this appliance is dam-

aged, it must be replaced by trained spe-

cialist staff.

Incorrect installation is dangerous.

Connect and operate the appliance only in

accordance with the specifications on the

rating plate.

Connect the appliance to a power supply

with alternating current only via a properly

installed socket with earthing.

The protective conductor system of the do-

mestic electrical installation must be prop-

erly installed.

Never equip the appliance with an external

switching device, e.g. a timer or remote

control.

When the appliance is installed, the mains

plug of the power cord must be freely ac-

cessible. If free access is not possible, an

all-pole isolating switch must be installed in

the permanent electrical installation accord-

ing to the conditions of Overvoltage Cat-

egory III and according to the installation

regulations.

When installing the appliance, check that

the power cable is not trapped or dam-

aged.

19.6 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-

ing regulations and the regulations of the local elec-

tricity and gas suppliers.

¡

When discharging the exhaust air, the official and

legal regulations, such as the regional building

code., must be observed.

¡

In order to freely access the appliance for servicing,

select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid

damaging them during installation.

19.7 Instructions for the electrical

connection

In order to safely connect the appliance to the elec-

trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance

from the electricity supply. The appliance must only be

connected to a protective contact socket that has been

correctly installed.

The mains plug for the mains power cable must be

easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch

must be integrated into the permanent electrical in-

stallation according to the conditions of overvoltage

category III and according to the installation regula-

tions.

The permanent electrical installation must only be

wired by a professional electrician. We recommend

installing a residual-current circuit breaker (RCCB)

in the appliance's power supply circuit.

Sharp-edged components inside the appliance may

damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating

plate. → 

Page 13

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference

suppression regulations.

¡

The appliance corresponds to protection class 1.

You should therefore only use the appliance with a

protective earth connection.

¡

Do not connect the appliance to the power supply

during installation.

¡

Ensure that the protection against contact is guaran-

teed during installation.

19.8 Information on the installation situation

¡

Install this appliance on the kitchen wall.

¡

The appliance must be installed before the upper

cabinets, if these are deeper than 370 mm.

¡

To install additional special accessory parts, ob-

serve the enclosed installation instructions.

¡

The appliance must be installed with no more than

one side directly next to a tall unit, an upper cabinet

or a wall. The distance between the appliance and

the tall cabinet, upper cabinet or the wall must be at

least 50 mm.

¡

The width of the extractor hood must correspond at

least with the width of the hob.

¡

To optimally detect the cooking vapours, install the

appliance in the middle of the hob.

19.9 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-

ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a

pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or

small pipe diameters reduce the suction power and

increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-

ible material.

¡

To prevent condensate from returning, fit the ex-

haust pipe with a 1° gradient from the appliance.

Содержание D98IPT2S0B

Страница 1: ...Extractor hood User manual and installation instructions D98IPT2S0 D98IPT2S0B D98IPT2Y5...

Страница 2: ...cooking vapour in private households and in enclosed spaces in a domestic environment up to an altitude of max 4000 m above sea level 1 3 Restriction on user group This appliance may be used by childr...

Страница 3: ...ot let children play with small parts WARNING Risk of poisoning Risk of poisoning from flue gases being drawn back in Room air dependent heat pro ducing appliances e g gas oil wood or coal operated he...

Страница 4: ...isk of electric shock If the appliance or the power cord is dam aged this is dangerous Never operate a damaged appliance Never pull on the power cord to unplug the appliance Always unplug the applianc...

Страница 5: ...n speed in good time The odours are distributed around the room less Switch off the lighting if it is no longer required When the lighting is switched off it does not con sume any energy Clean or repl...

Страница 6: ...the filter saturation indicator Switching the appliance on or off Home Connect Selecting the favourites function Switching on fan setting 1 Switching on fan setting 2 Switching on fan setting 3 Switch...

Страница 7: ...pending on the setting of the sensor sensit ivity the optimum fan setting is automatically switched on You can change the sensor sensitivity setting in the Home Connect app Factory setting 3 Lowest se...

Страница 8: ...and is used to dry the odour filter after the cooking process 8 7 Interval ventilation In order to regularly ventilate your kitchen you can use the interval ventilation With interval ventilation the v...

Страница 9: ...act them have your ap pliance connected to the Home Connect server and if Remote Diagnostics is available in the country in which you are using the appliance Tip For further information and details ab...

Страница 10: ...lectric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance WARNING Risk of burns The appliance becom...

Страница 11: ...grease filter Page 10 1 Observe the information regarding the cleaning agents Cleaning products Page 10 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filte...

Страница 12: ...y a It may take a few minutes until all of the functions are available General malfunctions occur A software update may be required Update the software Software update Page 9 Di s pos al 13 Disposal 1...

Страница 13: ...Plus air recircu lation set Z51BII1X6 Clean Air Plus recircula tion kit flue free angled extractor hood Z51BIV1X6 Accessories Order number Long Life recirculation kit flue free angled ex tractor hood...

Страница 14: ...sger te GmbH Carl Wery Str 34 81739 Munich Germany The source code will be made available to you on re quest Please send your request to ossrequest bshg com or BSH Hausger te GmbH Carl Wery Str 34 817...

Страница 15: ...n instructions en 15 19 2 Included with the appliance After unpacking all parts check for any damage in transit and completeness of the delivery 19 3 Dimensions You will find the dimensions of the app...

Страница 16: ...eric pressure Toxic gases from the chimney or the extrac tion shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air...

Страница 17: ...tall unit an upper cabinet or a wall The dis tance between the appliance and the tall cabinet an upper cabinet or the wall must be at least 50 mm WARNING Risk of injury Components inside the appliance...

Страница 18: ...for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallatio...

Страница 19: ...n the installation situation Page 18 2 Ensure that there are no electrical wires gas pipes or water pipes in the area where holes are to be drilled 3 Cover the hob to prevent damage 4 Determine the po...

Страница 20: ...ight of the appliance from above using a screw driver 5 Secure the appliance from above using 2 nuts 6 Note Do not knock the gas pressure dampers against the painted inner frame Clip the gas pressure...

Страница 21: ...onnection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Installing the flue duct WARNING Risk...

Страница 22: ...e design profiles observe the enclosed in structions for the accessory Removing the appliance Note The design profiles are not hand grip elements Do not lift the appliance by the design profiles 1 Rem...

Страница 23: ......

Страница 24: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001809512 9001809512 031019 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...