Prior to installation

Preparing the ceiling

The ceiling must be flat and horizontal.

Ensure that the ceiling is capable of pro-
viding a firm hold for mounting screws
and plugs. The enclosed plugs are sui-
table for concrete and stonework. If the
ceiling is made of any other material,
use appropriate mounting components.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:

1.

Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 
terminal marked ‘L’, or coloured red.

The extractor hood 

should only be

connected to an earthed socket that has
been installed according to relevant 
regulations.
If possible, site the earthed socket directly
above the chimney panelling in the ceiling.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.
If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be 
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the house-
hold circuit. A suitable separator is a switch
that has a contact gap of more than 3 mm
and interrupts all poles. Such devices 
include circuit breakers and contactors.

If the connecting cable for this applian-

ce is damaged, the cable must be replaced
by the manufacturer or his customer

service or a similarly qualified person in

order to prevent serious injury to the user.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.

Changing over from exhaust-
air to recirculating mode

Changing the electronic control system
to recirculating mode:

The standard factory setting is for
operation in exhaust-air mode.

To change the mode, the extractor hood
must have been connected up and
should be switched off.

1.

Press and hold the 

0

button.

2.

While 

{

is displayed, press the

button until 

ã

is displayed. When this

has taken place, release the buttons.

ã

goes out shortly afterwards.

The electronic control system will then
have been set to recirculating mode.

By repeating steps 

1

and 

2, 

you can

change the electronic control system
back to exhaust-air mode (

#

in display).

Weight in kg:

Exhaust air

Recirculating air

38,6

39,3

We reserve the right to construction changes within the 
context of technical development.

13

Содержание D91T7

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D91T7 NEFF UK Ltd...

Страница 2: ...2 Abb 1 ELECTRO Fig 1 GAZ...

Страница 3: ...poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the ov...

Страница 4: ...aneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care o...

Страница 5: ...g off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Operating procedure Acoustic signal When a button is pressed this is verifi...

Страница 6: ...leaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they...

Страница 7: ...filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see optional accessories Use original filters only By doing so you will obtain maximum...

Страница 8: ...same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and...

Страница 9: ...or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to cha...

Страница 10: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment...

Страница 11: ...air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be a...

Страница 12: ...t of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adeq...

Страница 13: ...isconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be c...

Страница 14: ...gas hotplates 1 Mark the centre point of the extractor hood on the ceiling 2 Using the template mark screw positions on the ceiling 3 Drill 4x 8 mm holes and insert wall plugs flush with the ceiling 4...

Страница 15: ...the support frame at the specified overall height with 8 screws 10 Align the extractor hood To do this loosen the ceiling screws in the support frame 09 Screw the extractor hood to the support frame a...

Страница 16: ...ve foil 15 Push up the upper flue section and screw into position 16 Insert the two sections of the lower flue and clip together Protect the extractor hood from damage 14 Place the two sections of the...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...19 351210 Z5120X5...

Страница 20: ...9000 032 337 Printed in Germany 0905 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: