Prior to installation

The exhaust air is discharged upwards
through a ventilation shaft or directly
through the outside wall into the open.

D

Exhaust air should neither be directed

into a smoke or exhaust flue that is
currently used for other purposes, nor into
a shaft that is used for ventilating rooms in
which stoves or fireplaces are also located.

Exhaust air may be discharged in 
accordance with official and statutory
regulations only (e.g. national building
regulations).

Local authority regulations must be
observed when discharging air into smoke
or exhaust flues that are not otherwise in
use.

D

When the extractor hood is operated

in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney 

(such as gas, oil or

coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to

ensure that there is an adequate supply
of fresh air 

which will be needed by the

burner for combustion.

Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).

This can be achieved if combustion air can
flow through non-lockable openings, e.g. in
doors, windows and via the air-
intake/exhaust-air wall box or by
other technical measures, such
as reciprocal interlocking, etc.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself
is no guarantee that the limiting value will
not be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.

Unrestricted operation is possible if the
extractor hood is used in recirculating
mode – with activated carbon filter.

If the exhaust air is going to be
discharged into the open, 

a telescopic

wall box should be fitted into the outside
wall.

Exhaust-air mode

Содержание D91T7

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D91T7 NEFF UK Ltd...

Страница 2: ...2 Abb 1 ELECTRO Fig 1 GAZ...

Страница 3: ...poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the ov...

Страница 4: ...aneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care o...

Страница 5: ...g off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Operating procedure Acoustic signal When a button is pressed this is verifi...

Страница 6: ...leaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they...

Страница 7: ...filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see optional accessories Use original filters only By doing so you will obtain maximum...

Страница 8: ...same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and...

Страница 9: ...or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to cha...

Страница 10: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment...

Страница 11: ...air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be a...

Страница 12: ...t of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adeq...

Страница 13: ...isconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be c...

Страница 14: ...gas hotplates 1 Mark the centre point of the extractor hood on the ceiling 2 Using the template mark screw positions on the ceiling 3 Drill 4x 8 mm holes and insert wall plugs flush with the ceiling 4...

Страница 15: ...the support frame at the specified overall height with 8 screws 10 Align the extractor hood To do this loosen the ceiling screws in the support frame 09 Screw the extractor hood to the support frame a...

Страница 16: ...ve foil 15 Push up the upper flue section and screw into position 16 Insert the two sections of the lower flue and clip together Protect the extractor hood from damage 14 Place the two sections of the...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...19 351210 Z5120X5...

Страница 20: ...9000 032 337 Printed in Germany 0905 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: