Important information

Installation Instructions:

Additional information concerning gas
cookers:

When installing gas hotplates, comply

with the relevant national statutory 
regulations (e.g. in Germany: Technische
Regeln Gasinstallation TRGI).

Always comply with the currently valid

regulations and installation instructions
supplied by the gas appliance 
manufacturer.

Only one side of the extractor hood

may be installed next to a high-sided unit
or high wall. Gap at least 50 mm.

Minimum distance on gas hotplates

between the upper edge of the trivet 
and lower edge of the extractor 
hood:     

650 mm, 

Fig. 1.

Old appliances are not worthless

rubbish. Valuable raw materials can be
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.

You received your new appliance in a

protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.

Please ask your dealer or inquire at your
local authority about current means of 
disposal. 

The extractor hood can be used in

exhaust air or circulating air mode.

Always mount the extractor hood over

the centre of the hob.

Minimum distance between electric

hob and bottom edge of extractor hood:

550 mm,

Fig. 1.

The extractor hood must not be 

installed over a solid fuel cooker – a 
potential fire hazard (e.g. flying sparks) –
unless the cooker features a 

closed, 

non-removable cover

and all national

regulations are observed.

The smaller the gap between the

extractor hood and hotplates, the greater
the likelihood that droplets will form on the
underside of the extractor hood.

Содержание D91T7

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D91T7 NEFF UK Ltd...

Страница 2: ...2 Abb 1 ELECTRO Fig 1 GAZ...

Страница 3: ...poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the ov...

Страница 4: ...aneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care o...

Страница 5: ...g off Repeat the process with the light switched on After approx 3 seconds the light switches off to acknowledge the setting Operating procedure Acoustic signal When a button is pressed this is verifi...

Страница 6: ...leaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dish washer It is however possible that they...

Страница 7: ...filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see optional accessories Use original filters only By doing so you will obtain maximum...

Страница 8: ...same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and...

Страница 9: ...or if a fault occurs please call Customer Service See list of Customer Service representatives When you call please quote the following Setting the saturation indicator If it becomes necessary to cha...

Страница 10: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment...

Страница 11: ...air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be a...

Страница 12: ...t of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adeq...

Страница 13: ...isconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m If it is necessary to wire the extractor hood directly into the mains The extractor hood should only be c...

Страница 14: ...gas hotplates 1 Mark the centre point of the extractor hood on the ceiling 2 Using the template mark screw positions on the ceiling 3 Drill 4x 8 mm holes and insert wall plugs flush with the ceiling 4...

Страница 15: ...the support frame at the specified overall height with 8 screws 10 Align the extractor hood To do this loosen the ceiling screws in the support frame 09 Screw the extractor hood to the support frame a...

Страница 16: ...ve foil 15 Push up the upper flue section and screw into position 16 Insert the two sections of the lower flue and clip together Protect the extractor hood from damage 14 Place the two sections of the...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...19 351210 Z5120X5...

Страница 20: ...9000 032 337 Printed in Germany 0905 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...