background image

3

Appliance description

Operating Instructions

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the kit-
chen vapours and conveys them through
the grease filter into the atmosphere.

The grease filter absorbs the solid 
particles in the kitchen vapours.

The kitchen is kept almost free of grease
and odours.

D

When the extractor hood is operated

in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney 

(such as gas, oil or

coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to

ensure that there is an adequate supply
of fresh air 

which will be needed by the

burner for combustion.

Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).

Operating modes

This can be achieved if the combustion air
is able to flow through non-lockable 
openings, e.g. in doors, windows and in
conjunction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.

Unrestricted operation is possible if the
extractor hood is used in recirculating mode
– with activated carbon filter.

Circulating-air mode:

An activated carbon filter must be fitted
for this operating mode (see Filters and
maintenance).

The complete installation set and 

replacement filters can be obtained 

from 

specialist

outlets.

The corresponding accessory numbers
can be found at the end of these 
operating instructions.

The extractor-hood fan extracts the 
kitchen vapours which are purified in the
grease filter and activated carbon filter
and then conveyed back into the 
kitchen.

The grease filter absorbs the grease 
particles in the kitchen vapours.

The activated carbon filter binds the
odorous substances.

If no activated carbon filter is installed, 

it is not possible to bind the odorous 
substances in the cooking vapours.

Lighting

Light / fan

switches

Filter grille

Chimney
panelling

Содержание D8662N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D8662 D8762 D8962 NEFF UK Ltd...

Страница 2: ...2 Abb 1 ELECTRO Fig 1 GAZ mind 650 mind 550...

Страница 3: ...is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When asse...

Страница 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Страница 5: ...d together with other dishes etc When cleaning the filters by hand soak them in hot soapy water first of all Do not use aggressive acidic or caustic cleaners Then brush the filters clean rinse them th...

Страница 6: ...Insert the clean filters back into the hood Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and more saturated with grease there is an increas...

Страница 7: ...ild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished We recommend our stainless steel cleaner no 461731 See enclosed service booklet for...

Страница 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Страница 9: ...of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This...

Страница 10: ...0 mm Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters...

Страница 11: ...appliance after removal of the filter frame Before undertaking any repairs always disconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m This extractor hood co...

Страница 12: ...e minimum distance bet ween the hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor...

Страница 13: ...e panelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template...

Страница 14: ...14 Notes...

Страница 15: ...15 360732 Z 5116X5 1 2 3 4 5 6 2x 10x 2x...

Страница 16: ...9000 152 342 Printed in Germany 0306 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: