Electrical connection

The extractor hood 

should only be

connected to an earthed socket that has
been installed according to relevant
regulations.

If possible, site the earthed socket directly
behind the chimney panelling.

The earthed socket should be 
connected via its own circuit.

If the earthed socket is no longer 
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.

If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.

A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.

If the connecting cable for this 

appliance is damaged, the cable must be
replaced by the manufacturer or his 
customer service or a similarly qualified
person in order to prevent serious injury to
the user.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.

This extractor hood corresponds to EC
regulations concerning RF interference
suppression.

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.

This is what you have to do:

1.

Connect the green and yellow (Earth)

wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the

terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 

terminal marked ‘L’, or coloured red.

Weight in kg:

Exhaust air

Recirculating air

20,5

60 cm

70 cm

21,0

21,5

22,5

90 cm

23,0

23,5

We reserve the right to construction changes within the 
context of technical development.

Prior to installation

Preparing the wall

The wall must be flat and perpendicular.

Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.

Содержание D8662N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods D8662 D8762 D8962 NEFF UK Ltd...

Страница 2: ...2 Abb 1 ELECTRO Fig 1 GAZ mind 650 mind 550...

Страница 3: ...is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When asse...

Страница 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Страница 5: ...d together with other dishes etc When cleaning the filters by hand soak them in hot soapy water first of all Do not use aggressive acidic or caustic cleaners Then brush the filters clean rinse them th...

Страница 6: ...Insert the clean filters back into the hood Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and more saturated with grease there is an increas...

Страница 7: ...ild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished We recommend our stainless steel cleaner no 461731 See enclosed service booklet for...

Страница 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Страница 9: ...of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This...

Страница 10: ...0 mm Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters...

Страница 11: ...appliance after removal of the filter frame Before undertaking any repairs always disconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m This extractor hood co...

Страница 12: ...e minimum distance bet ween the hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor...

Страница 13: ...e panelling together slots in the upper section must be pointing downwards and insert into the opening in the extractor hood Protect the cover panels from scratches for example by laying the template...

Страница 14: ...14 Notes...

Страница 15: ...15 360732 Z 5116X5 1 2 3 4 5 6 2x 10x 2x...

Страница 16: ...9000 152 342 Printed in Germany 0306 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: