Doc. no#: 310-0050-001-002 R103 Manual
Page 8
Onboard relays
On each of the four relays you have
access to both the NO (Normal open
contacts) and the NC (Normal close
contacts). This gives you the
opportunity to use it according to
your needs.
When using the 4 relays you can select what type of voltage you want to use at installation time.
The flexibility of the Neets Control - ZULU offers you the possibility to control high voltage or low voltage
(Please note that high and low voltage cannot be used simultaneously).
Note that the relay box’s relay 1 and 2 from factory is
configured to control a 230 VAC screen or lift. Using the
“Screen” connector and therefore you must not use the
“RELAY 1” and “RELAY 2” connectors.
If you do not want to use the “Screen” connector, please
remove fuses F402 and F403 “SCREEN FUSES 2*5AT”.
Read the section “Controlling an electrical screen or lift”
for further details.
Controlling an electric screen or lift
The relays offer your easy connection of an electrical screen or lift.
By using the screen terminals, you get an easy connection of your screen, and even more high security mode
prevents you from accidentally making short circuit.
The relay 1 (RELAY 1) is now controlling the screen in one direction, and there is
ONLY power to the screen´s other direction (RELAY 2) when relay 1 (RELAY 1) is
“released”. Be sure to set up the software to fit this hardware configuration.
To enable the screen mode insert the fuses F402 and F403 (SCREEN FUSES 2*5AT)
Com
NC
NO
Содержание Zulu