42
EN Operating Instructions
7 Switch on the PRIMUS 2 HVA2N
AUTOMATIC operating mode, ROTATION mode is the default setting each
time the laser is switched on.
NOTE
Despite careful setting up, warnings and error messages can appear in the display in
AUTOMATIC operating mode due to external influences and strong vibrations. For
description and remedies, see Chapter 16.
7.1 AUTOMATIC operating mode
In AUTOMATIC operating mode, the laser automatically levels itself horizon-
tally within a range of ±5° and compensates for minor vibrations. If the laser is
installed/set up vertically, the integrated position sensor recognises this.
HVA2N
HVA2N
Switch on the laser
Laser levels itself
horizontally
Levelling is finished, the flashing symbol goes
out, the laser is active
If the levelling is finished, the laser can be placed in the final vertical position/
height within a period of 30 seconds, e.g. using an elevator tripod.
After 30 seconds, the TILT alarm function is switched on. A vertical move-
ment of the laser triggers the warning C01. For description and remedies, see
Chapter 16.
AUTOMATIC operating mode is active. The following functions can be
invoked:
Use the
button to switch to MANUAL operating mode (Chapter 7.2).
Use the
button to invoke the VARIABLE SPEED function (Chapter 8.1).
Use the
button to invoke the SCANNING function (Chapter 8.2).
Use the
button to invoke the TILT X-axis function (Chapter 8.3).
Use the
button to exit the operating mode, switch off the laser.