9
Silent mode
In silent mode, the product does not sound the alarm
for 10 minutes. When smoke or CO is detected in silent
mode,
A
1
blinks red.
The silent mode must be activated manually.
1. Press the test/silence button
A
2
shortly to activate
silent mode.
After 10 minutes, the product goes back into standby
mode.
LED light
Sound alarm
Standby mode
A
1
blinks
green every 40
seconds.
Off.
Hush mode
A
1
blinks
yellow every 40
seconds.
Off.
Test
A
1
pulses
red 3 times,
followed by
a 1.5 second
pause. After
this cycle,
A
1
pulses red 4
times, followed
by a 5 second
pause.
3 long beeps
and 4 long
beeps.
Low battery
condition
A
1
blinks
yellow every 40
seconds.
Beeps once
every 40
seconds.
Malfunction
A
1
blinks
yellow 2 times
every 40
seconds.
Beeps 2 times
every 40
seconds.
End-of-life
A
1
blinks
yellow 3 times
every 40
seconds.
3 short beeps
every 40
seconds.
Smoke alarm
A
1
blinks red
3 times in a
row, followed
by a 1.5 second
pause.
Beeps 3 times in
a row, followed
by a 1.5 second
pause.
CO Alarm
A
1
blinks red
4 times in a row,
followed by
a five second
pause.
Beeps 4 times in
a row, followed
by a 5 second
pause.
Response time of the product in case
of CO
Concentration of CO
in air. (ppm = parts per
million)
Response time of the
product
30ppm
120 minutes
50ppm
60 – 90 minutes
100ppm
10 – 3 minutes
300ppm
3 minutes
CO Alarm
When the alarm beeps four times in a row and the
indicator blinks red:
•
Immediately go outside.
•
Call the local emergency services (Fire department).
•
Do not go back into the building until the
emergency services tell you it is safe.
Smoke alarm
When the alarm beeps three times in a row and the
indicator blinks red:
•
Identify the source of the smoke.
Содержание DTCTCS10WT