![nedis DTCTCO40WT Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/nedis/dtctco40wt/dtctco40wt_manual_716262010.webp)
10
Concentration of CO
in air. (ppm = parts per
million)
Symptoms
400ppm
Within 1-2 hours of
exposure:
-
frontal headaches
WARNING
: 3 hours of
exposure will result in
death.
800 – 999 ppm
Within 45 minutes of
exposure:
-
dizziness
-
nausea
-
convulsions
-
unconsciousness
WARNING:
2-3 hours
of exposure will result
in death.
-
The product is designed to protect users against
the acute effects of CO poisoning. The product does
not ensure complete protection for people with
medical issues.
Installing the batteries
(image
B
)
1. Turn the alarm
A
5
counter clockwise to remove it
from the bracket
A
6
.
2. Insert the batteries into the battery compartment.
Make sure that the battery polarity (+/-) matches the
polarity markings inside the battery compartment.
3. Turn
A
5
clockwise to attach it to
A
6
.
-
Constant exposure to high or low humidity may
reduce battery life.
Mounting the product
(image
C
+
D
)
1. Turn
A
5
counterclockwise to remove it from
A
6
.
2. Place
A
6
in the desired location.
Follow steps 3-5 for stone/concrete surfaces. Continue
to step 6 for wood surfaces.
3. Use
A
6
to mark the drill locations with a pencil.
4. Drill two Ø 5 mm holes.
5. Insert the plugs
A
q
into the holes.
6. Fasten the mounting bracket with the screws
A
9
.
7. Turn
A
5
clockwise to attach it to
A
6
.
Make sure the arrow on the bracket is pointing upwards
when installing to the wall.
4
Keep the product in a dust free area when drilling.
Do not overtighten the screws, this will deform the
bracket.
Choosing a location
(image
E
+
F
)
For safe use, it is recommended to install the product in
the following locations:
•
Every sleeping area.
•
Both ends of a hallway longer than 12 m.
•
Every room where multiple people spend several
consecutive hours.
•
Install at least one product on each floor of a
multi-level home.
•
Every room where a furnace, a heat source and/or
other burning devices are located.
•
If there is a basement in the house: At the top of the
basement stairs.
-
The product only indicates the presence of CO near
the sensor. CO may be present in other areas.
In areas with a source of combustion
On the ceiling:
•
At least 1 - 3 m away from the CO-source. The
optimal distance is 6 m.
•
At least 30 cm away from surrounding walls.
•
At a central point in the room.
•
Not in turbulent air (near windows, ceiling fans or air
conditioners).