FlexPAK 800/1000 DX
EN
22
16.
Control Filter and filter cartridge, see figure 4B.
17.
Pressure sensor, see figure 4B.
18.
Acoustic enclosure, see figure 4B.
19.
Cooling air hose from the frequency converter cabinet, see figure 4C.
20.
Compressed air supply, see figure 4C.
21.
Inlet, see figure 4C.
3.8
Connections
NOTE!
The exhaust air duct is to be routed straight and as short a distance as possible.
NOTE!
The unit is CE-marked. Connections to the unit, initial start-up and maintenance are
to be carried out according to the product manuals.
Equipment such as cables and hoses are not supplied and are to be obtained locally.
Figure
9
shows the normal connections to the unit. They are as follows:
1.
Duct from workstations.
2.
Isolation device.
3.
Pressure resistent duct between the unit and the isolation device.
4.
Exhaust air duct, Ø 160 mm (for lengths <12 m).
5.
PS cable from valves at workstations.
6.
Incoming 3-phase power supply with a Protective Earth (PE) cable.
7.
Compressed air supply, Ø 6 mm nylon hose.
8.
Compressed air valve, size G1/4” or G1/2”.
9.
Water and dirt trap. Compressed air supply is to be clean and dry.
10.
Maintenance switch according to standard.
11.
Power cable to the unit.
3.9
Start and control unit
The unit has a start and control unit, see figure
5
. The start and control unit has the
following components:
1.
Transformer TR1, 60 W.
2.
Connection block for the transformer TR1.
3.
Transformer primary fuses F2 and F3.
4.
Terminals for external emergency stop.
5.
Programmable Logic Controller (PLC).
6.
Data Unit 2 (DU2), I/O module.
7.
AM 2 PT100, temperature sensor input expansion module.
8.
Filter cleaning/test start button.
9.
Standby/Running button, which is the On/Off button.
10.
Emergency switch.
11.
Terminals: X1: 1-80.
12.
Fuse for 24 V DC accessory supply: Fuse F5.
13.
Fuse for Pilot Signal (PS) cable: Fuse F4.
14.
Terminals Protective Earth (PE).
Содержание FlexPAK 800 DX
Страница 2: ...FlexPAK 800 1000 DX 2...
Страница 9: ...FlexPAK 800 1000 DX 7 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11...
Страница 10: ...FlexPAK 800 1000 DX 8 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10...
Страница 11: ...FlexPAK 800 1000 DX 9 1 2 3 4 5 6 7 14 13 12 11 9 8 10 5 A B 6 7...
Страница 13: ...FlexPAK 800 1000 DX 11 9 10 1643 1mm 65 662 1mm 26 2 1771 4 1mm 70 13mm 4 1 2 3 6 7 8 10 9 11 5 1...
Страница 14: ...FlexPAK 800 1000 DX 12 11 12 14 13...
Страница 15: ...FlexPAK 800 1000 DX 13 1 0m 39 4 A B C 16 17 15 Min 2 1m 83 A A A A C...
Страница 40: ...FlexPAK 800 1000 DX EN 38...
Страница 64: ...FlexPAK 800 1000 DX CS 62...
Страница 88: ...FlexPAK 800 1000 DX DA 86...
Страница 160: ...FlexPAK 800 1000 DX FI 158...
Страница 280: ...FlexPAK 800 1000 DX NO 278...
Страница 306: ...FlexPAK 800 1000 DX PL 304...
Страница 340: ...FlexPAK 800 1000 DX RU 338 4 FlexPAK 800 1000 DX Nederman Nederman PS 6 7 5 Nederman EN 14491 FlexPAK 800 1000 DX...
Страница 341: ...FlexPAK 800 1000 DX 339 RU FlexPAK 800 1000 DX FlexPAK 800 1000 DX 5 1 9 10...
Страница 342: ...FlexPAK 800 1000 DX RU 340 5 2 5 5 2 1 6 1 3 Running 5 8 8 6 3 1 5 2 2 PLC Standby Running 8 8 3 10 12 DIR SSR 10 12 SSR...
Страница 348: ...FlexPAK 800 1000 DX RU 346 7 7 1 1 2 3 Program 4 Set Parameter 5 6 7 8 9 10...
Страница 351: ...FlexPAK 800 1000 DX 349 RU 2 X1 13 X1 14 3 3 10 DIR 12 SSR 12 DIR 10 8 4 DO3 24 9...
Страница 353: ...FlexPAK 800 1000 DX 351 RU Nederman 2 3 11 1 2 3 4 12 5 6 7 14 8 9 3 15 16 17 A C A C 9 4 6000 1 FlexPAK 800 1000 DX...
Страница 356: ...FlexPAK 800 1000 DX RU 354...
Страница 389: ...FlexPAK 800 1000 DX 387 CN 5 Nederman EN 14491 FlexPAK 800 1000 DX FlexPAK 800 1000 DX FlexPAK 800 1000 DX 5 1 9 10 PS...
Страница 399: ...FlexPAK 800 1000 DX 397 CN 9 2 Nederman 2 3 11 1 2 3 4 12 5 6 7 14 8 9 3 15 16 17 A C A C 9 4 6 000...
Страница 402: ...FlexPAK 800 1000 DX CN 400...
Страница 403: ......
Страница 404: ...www nederman com...