24
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Blinking
r E A
0
1
0
1
p F a i l
Blinking
r E A
is diplayed (alternating with the
number of operating hours) in combination
with a motor error and a desplayed
A-alarm at remote controlling.
There has been a power failure.
Reset by pressing the 0/1 button. If
the filter is remotely started it will start
directly when the 0/1 button is pressed.
The dust collector is full.
Empty the collector.
The door is open and FilterMax DX
will not start.
The door has been opened during
system operation. Shut the door.
Service requirements! Should be rectified
as soon as possible.
Example:
• One valve is defective or does not work. It is
displayed what valve that is defect (Err + the
defected valve no. (1 - 18) is displayed, switching
with the number of operating hours).
Содержание FilterMax DX 3000
Страница 36: ...36 INSTALLATION AND SERVICE PROTOCOL 4 Point no Date Note ...
Страница 37: ......