OPERATING DESCRIPTION
It is recommended to use a downtime
damper which should be mounted close to
the inlet (see picture page 16). The damper
closes the duct when FilterMax DX is shut
off, which will prevent dust from being
transported back into the workshop by the
air pulses from the down time cleaning.
The contaminated air is led through the inlet which is
shaped to distribute the air evenly into the filter. Inside
the inlet there are four blades that further enhance the
air distribution. This design also minimises the
pressure loss in the inlet.
The filter cartridge seen from above
The filter cartridges are cleaned one
by one with powerful air pulses. The
air pulses are distributed into the slot
shaped outlet of the filter cartridges.
The distribution generates a quiet and
efficient cleaning pulse.
The filter controller controls the
cleaning process.
Valve with
cleaning pipe
Explsion relief panel, unloads the
pressure at an explosion.
The cleaned air exits
through the outlet in
the top of the front
part of FilterMax DX.
The air stream is led down-
wards by the sloped roof of
FilterMax DX towards the
filter cartridges. The filter
media in the cartridges
collects the remaining
particles.
Collection chamber
leading down to the
dust container.
Dust collector
Filter
protection
panels.