8.2

Disposal

When the PowerRouter reached the end of its service life, or is defect beyond repair:

Dispose of the PowerRouter according to local regulations.

Submit the PowerRouter to a collection point for electrical and electronic waste recycling.

 

CAUTION

The PowerRouter must be disposed of according to local regulations.

Содержание PowerRouter PR50SB-PR/S24

Страница 1: ...Installation Manual PowerRouter Solar Battery Back up Stand alone Date 181213...

Страница 2: ...PowerRouter Back up Stand alone Installation Manual Illustrations Page 1 Installation Manual Original instructions Page 9 EN...

Страница 3: ...Standby 1 2 3 4 x 4 x 2 x 2 x 4 5 6 Standby Standby Standby Standby Standby Standby Standby Standby min 300 mm min 800 mm Max 40 C Min 10 C i 20 KG 20 KG A A A A A B B Drill template the PowerRouter D...

Страница 4: ...Illustrations PowerRouter Back up Stand alone Installation Manual 2 3 4 5 0 1 7 7 6 3 300A BAT BAT TMPS GND SH SH N L N L IMD 25A Relay AC Local out N L Load AC Local out RCD N L...

Страница 5: ...PowerRouter Back up Stand alone Installation Manual Illustrations 3 6 7 0 1 7 7 6 3 0 1 7 7 6 3 N L 0 1 7 7 6 3 N L 0 1 7 7 6 3 N L CAN N L N L N L 11 N fuse 315 mA 1 L1 4 L2 7 L3 9 L3 6 L2 3 L1...

Страница 6: ...up Stand alone Installation Manual 4 8 9 10 11 12 2 1 3 4 R1 R2 L N 5 6 R7 R8 A1 A2 N L N L AC local out AC grid external relay NO NC AC GRID AC LOCAL OUT NO NO NC NC L N L N K201 K202 0 1 7 7 6 3 N L...

Страница 7: ...er Back up Stand alone Installation Manual Illustrations 5 13 14 15 0 1 7 7 6 3 L3 L2 100 L1 N R7 R8 A1 A2 R1 R2 Ripple control receiver AC grid external relay N L AC GRID AC LOCAL OUT NO NO NC NC 6 3...

Страница 8: ...18 RJ45 Pin Orange White Tracer 1 Orange 2 Green White Tracer 3 Blue 4 Blue White Tracer 5 Green 6 Brown White Tracer 7 Brown 8 GND GND GND GND C D 1 2 5 6 4 3 A B N L N L CBEU 02 CSAP 01 NO NC AC GR...

Страница 9: ...PowerRouter Back up Stand alone Installation Manual Illustrations 7 19 20 21 22...

Страница 10: ...Illustrations PowerRouter Back up Stand alone Installation Manual 8 23 24...

Страница 11: ...3 phase sensor accessory PRA3SENSE 18 3 4 External relay accessory PRA1RLY 18 3 5 Wireless Energy Management Kit accessory PRA1WEMK 18 3 6 Batteries 18 3 7 Battery temperature sensor standard 18 4 In...

Страница 12: ...30 4 14 4 Register the PowerRouter on www myPowerRouter com 30 4 14 5 Register additional PowerRouters on one login 30 5 Software installation tool 32 5 1 Introduction 32 5 2 Display settings 32 5 2 1...

Страница 13: ...edures 43 7 6 1 Restart the PowerRouter 43 7 6 2 Check the PowerRouter airflow 43 7 6 3 Check the internet connection 43 7 6 4 Look up the firmware versions and id number 43 7 6 5 Reset the PowerRoute...

Страница 14: ...e instructions are not followed could result in injury and damage to the equipment CAUTION This symbol indicates a situation which if the instructions are not followed could result in damage to the eq...

Страница 15: ...e e g lightning overvoltage storm fire Cosmetic shortcomings which do not influence the functioning of the unit Damage due to moisture and or other environmental conditions i The installer dealer who...

Страница 16: ...related to its use No data published in this manual may be reproduced or published in any form or by any means without the prior written consent of Nedap Information in this manual is subject to chang...

Страница 17: ...There are two labels on the PowerRouter figure 1 A warning label with battery warnings A type label that provides technical specifications i The image shows an example of the labels The labels may be...

Страница 18: ...els used in the system 2 6 Batteries DANGER Batteries deliver electric power and can cause an energy or fire hazard when they are shorted or wrongly installed WARNING Series fuse protection is require...

Страница 19: ...rRouter The PowerRouter can even be remotely updated with new firmware containing the latest features so the system is always kept up to date 3 1 2 PowerRouter software installation tool The software...

Страница 20: ...ed The external relay can be ordered via your local Business Partner 3 5 Wireless Energy Management Kit accessory PRA1WEMK The Wireless Energy Management Kit can be used with PowerRouter products that...

Страница 21: ...s too high derating will occur The PowerRouter reduces the power output if the internal temperature becomes too high The location is not accessible for children The PowerRouter emits a slight hum duri...

Страница 22: ...ipped with a wall mounting bracket that is suitable for use on most walls To mount the PowerRouter 1 Use the drill template provided with the PowerRouter to drill the holes for the wall mounting brack...

Страница 23: ...itch to the AC local out terminal on the PowerRouter 7 Tighten the strain reliefs with a torque between 1 2 Nm and 1 5 Nm WARNING For continued protection against electric shock you must always use an...

Страница 24: ...and the batteries Use battery cables with a cross sectional area of 70 mm2 to 95 mm2 and a maximum length of 2 5 m per cable 2 Install a fuse 300 A slow blow in series with the positive battery cable...

Страница 25: ...the connection overview The sensor is configured by the PowerRouter and requires no setup only hard wiring is required 1 Disconnect the PowerRouter from the Public AC grid 2 Mount the 3 phase sensor i...

Страница 26: ...ucing the connected loads or intemitted use Connect the earth according local regulations The load that is connected to the relay must be 1 phase i For this function the value for energy export to the...

Страница 27: ...rd mounting box plastic 12 Connect the two wires to the PowerRouter programmable contact K201 13 Install the cover on the binary input module 14 Install the wireless plug in actuator in the desired wa...

Страница 28: ...ver 2 For 24V lead acid batteries set the external battery disconnect switch to on 3 Set the solar switch on the PowerRouter to on 4 Set the external AC disconnect switch to on 5 Switch on the PowerRo...

Страница 29: ...has a menu option re initialize If you use this wizard it only asks for basic battery settings based on these settings the PowerRouter updates other battery settings overwriting any customized batter...

Страница 30: ...isplay will show Selftest fail 1 Press yes and use up down to select Service 2 Press yes and use up down to select Selftest 3 Press yes to go to the Selftest 4 Press yes to continue or no to cancel 5...

Страница 31: ...ailes the second time contact your local Bussiness Partner 4 14 Connect the PowerRouter to the internet CAUTION Install the clip on coil on the UTP cable within 10 cm of the powerrouter 4 14 1 Connect...

Страница 32: ...heck the internet connection via menu service status internet connection The display should show OK 3 Go to a computer and open www myPowerRouter com 4 In the login screen click New user figure 19 5 F...

Страница 33: ...ided by the internet router or the intenet switch To test the connection connect a PC to the connection that you will use for the PowerRouter Open a web page If the web page opens the connection works...

Страница 34: ...re initialize If you use this wizard it only asks for basic battery settings based on these settings the PowerRouter updates other battery settings overwriting any customized battery settings Any cus...

Страница 35: ...to switch on additional loads when the grid voltage is high Which is usually an indication of high feed in power Battery State of Charge SoC Alarm based on the battery state of charge The alarm relay...

Страница 36: ...ings for a specific country CAUTION It is not allowed to select another country than the country the PowerRouter will be installed 5 4 2 EEG 2012 Set the dedicated parameters to your installation size...

Страница 37: ...atteries you can change The charging procedure to float charging The absorption voltage and float voltage The charge current CAUTION Wrong settings may harm the batteries 5 5 2 Maintenance charge Set...

Страница 38: ...the selected item Use NO to return to the previous item Select and change settings Use YES to change a selected setting Use the UP DOWN buttons to change the selected setting Use YES to confirm the ch...

Страница 39: ...n and ID number 7 2 Check the LED status When an error has occurred the LEDs will either be OFF or FLASHING as follows The LED can be on blinking or off The PowerRouter is receiving installing an upda...

Страница 40: ...safe mode and will not function until the user has turned the system off and on or a reset is performed A hard error is indicated when the error LED is flashing 7 4 2 Soft error When a soft error occu...

Страница 41: ...1 Run the installation tool or install wizard again Contact your dealer if this error occurs frequently P092 H G034 H B026 H S019 H Hard The PowerRouter configuration is incorrect Contact your dealer...

Страница 42: ...ontact your dealer if this error occurs frequently G007 S Soft The voltage level on the local out is too high in a situation where no voltage is expected If this error occurs during installation make...

Страница 43: ...peration will resume when the 10 minute average of the grid voltage is within approved limits G043 H Hard Error occurred in anti islanding settings Restart the system section 7 6 1 Run the installatio...

Страница 44: ...rature of the solar module S is too high The output power of the module has been reduced Check the airflow of the PowerRouter section 7 6 2 When the module cools down the error will disappear and the...

Страница 45: ...6 3 Check the internet connection The display will show information about the internet status like Internet connection status ok error counting Last date and time when the PowerRouter was connected to...

Страница 46: ...unit is completely de energised 7 Disconnect the communication wires 8 Disconnect any optional connections 9 Disconnect the solar panel string wiring with the special tool figure 8 10 Disconnect the A...

Страница 47: ...PowerRouter reached the end of its service life or is defect beyond repair Dispose of the PowerRouter according to local regulations Submit the PowerRouter to a collection point for electrical and ele...

Страница 48: ...50SB PR S24 PR37SB PR S24 PR30SB PR S24 Max input 5 5 kWp total 15 A per string 4 kWp total 15 A per string 3 3 kWp total 15 A No of inputs 2 2 1 No of MPP trackers 2 fully independent 2 fully indepen...

Страница 49: ...CE VDE AR N 4105 2011 08 EEG2012 C Tick Safety EN 60950 1 EN 62109 1 2 EN 60335 2 29 EN 62040 1 Emission EN 61000 3 2 EN 61000 3 3 EN 61000 6 3 EN 61000 3 12 Immunity EN 61000 6 2 EN 61000 3 11 Anti...

Страница 50: ...9 Technical specifications PowerRouter Back up Stand alone Installation Manual 48 EN...

Страница 51: ......

Страница 52: ...www PowerRouter com info PowerRouter com...