Set the uPASS reader to UHF mode
For uPASS Reach, set the dip switch as shown below. SW1-1 must be switched ON.
For uPASS Target, set the dip switch as shown below. SW1-1 must be switched OFF:
uPASS Access does not have a dip switch.
3.3
Configure the uPASS reader (for Nedap XS)
With the Nedap XS card format, you must apply specific settings on the reader to ensure that the
correct card information is sent to the Wiegand interface. Note that the reader must be set to
TRANSIT mode.
To configure the uPASS reader, take the following steps:
Retrieve card information (if necessary)
First, you need to know your card customer code. If you don’t know your card customer code, you
can use the dedicated Nedap UHFtool software to retrieve them. Nedap Identification Systems can
provide you with the correct tool.
Step
02
Step
01