NED
UME-0034-03
XCM8060SA_8040SA_6040SA
39
As it takes several seconds to rewrite the memory, do not disconnect the power
supply before receiving the response from the camera.
Commands for rewriting the memory are as follows.
Reset to factory settings
(
rst
)
Store present setup data in memory
(
sav
)
Store pixel correction data in memory
(wht)
When changing the factory setting exposure mode, be sure to send the
control input signal (CC1) from the frame grabber board. If you do not send CC1 or
sending control input signals are out of the designated range, you cannot get
images and can not change the setting. See 4.9.2 and 4.9.3.
Table 4-6-1 Camera Operation Mode and Control Input
Camera operation mode
(Exposure mode)
Control input
(from frame grabber board)
Free Run (Programmable time setting)
(
Factory Setting
)
Not in use
Ext Edge (External trigger edge+
Programmable time setting)
External trigger (CC1) is required
Ext Level (External trigger level time
setting)
External trigger (CC1) is required
4.7 Serial Communication Settings
Serial communication is performed through the Camera Link Interface
The table below shows the serial communication settings.
Table 4-7-1 Serial Communication Settings
Parameter Items
Setup Value
Communication Speed (Baud rate)
9600bps
Data Length
8bit
Parity Bit
None
Stop bit
1bit
Flow Control
None